UNT-SVX07E-EN 7
Model Number Descriptions
UniTrane™ Fan Coil/
Force Flo™ Cabinet
Heater
Following is a complete description of
the UniTrane fan coil and Force Flo
cabinet heater model number. Each digit
in the model number has a
corresponding code that identifies
specific unit options.
Note: Not all options are available on all
cabinet styles. Contact your local
Trane sales representative for
more information.
Digits 1, 2 — Unit Type
FC = UniTrane fan coil
FF = Force Flo cabinet heater
Digit 3 — Cabinet Type
A = Vertical concealed
B = Vertical cabinet
C = Horizontal concealed
D = Horizontal cabinet
E = Horizontal recessed
F = Wall-hung cabinet (FF only)
H = Vertical recessed
J = Vertical slope-top cabinet
M = Inverted vertical cabinet
(FF only)
N = Inverted vertical recessed
(FF only)
P = Compact concealed
Digit 4 — Development
SequenceB”
Digits 5, 6, 7 — Unit Size
Digit 8 — Unit Voltage
1 = 115/60/1
2 = 208/60/1
3 = 277/60/1
4 = 230/60/1
5 = 208/60/3 (FF only)
6 = 230/60/3 (FF only)
7 = 480/60/3 (FF only)
8 = 110-120/50/1 (FF only)
9 = 220/50/1
A = 220-240/50/3 (FF only)
B = 380-415/50/3 (FF only)
Digit 9 — Piping System/
Placement
A = No piping, RH, no auxiliary
drain pan
B = No piping, LH, no auxiliary
drain pan
C = No piping, RH, with auxiliary
drain pan
D = No piping, LH, with auxiliary
drain pan
E = No piping, RH, no auxiliary
drain pan, Extended End Pocket
F = No piping, LH, No Auxiliary
Drain Pan, extended end pocket
G = No piping, RH, with auxiliary
drain pan, extended end pocket
H = No piping, LH, with auxiliary
drain pan, extended end pocket
J = With piping package, RH
K = With piping package, LH
L = With piping package, RH,
extended end pocket
M = With piping package, LH,
extended end pocket
Digits 10, 11 — Design
Sequence
Digit 12 — Inlets
A = Front toe space
B = Front bar grille
C = Front stamped louver
D = Bottom stamped louver
E = Bottom toe space
F = Back duct collar
G = Back open return
H = Back stamped louver
J = Top duct collar (FF only)
K = Exposed fan (Model P only)
L = Bottom filter (Model P only)
Digit 13 — Fresh Air Damper
0=None
A = Manual, bottom opening
B = Manual, back opening
C = Manual, top opening
D = Auto, 2-position, bottom
opening
E = Auto, 2-position, back opening
F = Auto, 2-position, top opening
G = Auto, economizer, bottom
opening
H = Auto, economizer, back opening
J = Auto, economizer, top opening
K = No damper, bottom opening
L = No damper, back opening
M = No damper, top opening
Digit 14 — Outlets
A = Front duct collar
B = Front bar grille
C = Front stamped louver
D = Front quad grille
E = Bottom duct collar (FF only)
F = Bottom stamped louver
(FF only)
G = Top quad grille
H = Top bar grille
J = Top duct collar
Digit 15 — Color
0 = No paint (concealed units only)
1 = Deluxe Beige
2=Soft Dove
3=Cameo White
4 = Driftwood Grey
5 = Stone Grey
6=Rose Mauve
Digit 16 — Tamperproof Locks/
Leveling Feet
0=None
B = Keylock access door
C = Keylock panel and access door
D = Leveling feet
F = Keylock access door with
leveling feet
G = Keylock panel and access door
with leveling feet
Digit 17 — Motor
A = Free discharge ECM
B = High static ECM
Digit 18 — Coil
A = 2-row cooling/heating
1
B = 3-row cooling/heating
1
C = 4-row cooling/heating
1
D = 2-row cooling/1-row heating
E = 2-row cooling/2-row heating
F = 3-row cooling/1-row heating
G = 2-row cooling only
H = 3-row cooling only
J = 4-row cooling only
K = 2-row cooling/heating
1
with
electric heat
L = 3-row cooling/heating
1
with
electric heat
M = 4-row cooling/heating
1
with
electric heat
N = Electric heat, single-stage
(FF only)
P = 2-row cooling/heating
1
with
1-row heating
Q = 2-row cooling/heating
1
with
2-row heating
R = 3-row cooling/heating
1
with
1-row heating
U = Electric heat, two-stage
(FF only)
V = Electric heat, low kW, one-stage
(FF only)
W = Steam distributing (FF only)
X = 2-row cooling only, electric
heat
Y = 3-row cooling only, electric
heat
Z = 4-row cooling only, electric
heat
Note:
1
Designates coils provided with a
changeover sensor.
Digit 19 — Drain Pan Material
(Fan Coil) or Coil Series (Force
Flo)
1 = 108 FPF (steam only)
2 = 144 FPF (hot water only)
3 = Polymer drain pan
4 = Stainless steel main drain pan
020 040 080
030 060 100
120