Model Number Descriptions
10 UNT-SVX07E-EN
UniTrane™ Fan Coil
Low Vertical Model
Following is a complete description
of the UniTrane fan coil low height
vertical model.
Digits 1, 2 — Unit Type
FC = UniTrane Fan Coil
Digit 3 — Cabinet Type
K = Low vertical concealed
L = Low vertical cabinet
Digit 3 — Development
Sequence
B = Development sequence B
Digit 4, 5, 6 — Unit Size
030= Size 030
040= Size 040
060= Size 060
Digit 7 — Unit Voltage
1 = 115v/60hz/1ph
2 = 208v/60hz/1ph
3 = 277v/60hz/1ph
4 = 230v/60hz/1ph
Digit 8 — Piping system/
placement
C = Without piping, right hand, with
aux drain pan
D = Without piping, left hand, with
aux drain pan
J = With right hand piping
K = With left hand piping
Digit 9, 10 — Design Sequence
** = Factory assigned
Digit 11 — Inlet Style
A = Front toe space inlet
B = Front bar grille inlet
Digit 12 — Fresh Air Damper
0 = Without fresh air damper
B = Manual fresh air damper, back
opening
E = Auto, 2 position damper, back
opening
Digit 13 — Outlet Style
G = Top quad grille outlet
H = Top bar grille outlet
J = Top duct collar outlet
Digit 14 — Unit Color
0 = Unpainted unit (concealed units)
1 = Deluxe Beige
2=Soft Dove
3=Cameo White
4 = Driftwood Grey
5 = Stone Grey
6=Rose Mauve
Digit 15 — Tamperproof Locks
and Leveling Feet
0 = Without locks or leveling feet
B = Keylock access door
D = Leveling feet
F = Keylock access door with
leveling feet
Digit 16 — Main Coil Type
A = 2-row cooling/heating
1
B = 3-row cooling/heating
1
C = 4-row cooling/heating
1
D = 2-row cooling, 1-row heating coil
E = 2-row cooling, 2-row heating coil
F = 3-row cooling, 1-row heating coil
K = 2-row cooling/heating
1
with
electric heat coil
P = 2-row cooling/heating
1
with
1-row heating coil
Q = 2-row cooling/heating
1
with
2-row heating coil
R = 3-row cooling/heating
1
with
1-row heating coil
X = 2-row cooling only, electric heat
Note:
1
Designates coils provided with a
changeover sensor.
Digit 17 — Coil air vent
A = Auto air vent
M = Manual air vent
Digit 18, 19, 20 — Electric Heat
000= Without electric heat
010 = 1.0 kW [0.75 208v]
015 = 1.5 kW [1.1 208v]
020= 2.0 kW [1.5 208v]
025= 2.5 kW [1.9 208v]
030= 3.0 kW [2.2 208v]
040= 4.0 kW [3.0 208v]
Digit 21 — Auxiliary Coil Type
0 = Without auxiliary option
C = Electric heat
Digit 22 — Disconnect Switch
0 = Without disconnect switch
D = With disconnect switch
Digit 23 — Filter Type
0 = Without filter
1 = 1 inch. throwaway filter
Digit 24 — Main Control Valve
X = Field-supplied N/O control valve
Y = Field-supplied N/C control valve
Z = Field-supplied 3-wire modulating
control valve
1 = Field-supplied analog valve
(2-10VDC)
A = 2-way, 2-position, NO (30 psig)
Cv = 2.3
B = 3-way, 2-position, NO (28 psig)
Cv = 3.0
C = 2-way, 2-position, NC (30 psig)
Cv = 2.3
D = 3-way, 2-position, NC (20 psig)
Cv = 4.4
E = 2-way, 2-position, NO (50 psig)
Cv = 1.0
F = 3-way, 2-position, NO (28 psig)
Cv = 1.5
G = 2-way, 2-position, NC (50 psig)
Cv = 1.0
H = 3-way, 2-position, NC (28 psig)
Cv = 1.5
J = 2-way, modulating Cv=0.6
(60 psig)
K = 3-way, modulating Cv=0.6
(60 psig)
L = 2-way, modulating Cv=1.1
(60 psig)
M = 3-way, modulating Cv=1.1
(60 psig)
N = 2-way, modulating Cv=2.3
(60 psig)
P = 3-way, modulating Cv=2.7
(60 psig)
Q = 2-way, modulating Cv=3.3
(60 psig)
R = 3-way, modulating Cv=3.8
(60 psig)
0 = Without cooling control valves
2 = 2 way, analog(2-10VDC), Cv=0.6
(60 psig)
3 = 3 way, analog(2-10VDC), Cv=0.6
(60 psig)
4 = 2 way, analog(2-10VDC), Cv=1.1
(60 psig)
5 = 3 way, analog(2-10VDC), Cv=1.1
(60 psig)
6 = 2 way, analog(2-10VDC), Cv=2.3
(60 psig)
7 = 3 way, analog(2-10VDC), Cv=2.7
(60 psig)
8 = 2 way, analog(2-10VDC), Cv=3.3
(60 psig)
9 = 3 way, analog(2-10VDC), Cv=3.8
(60 psig)