EasyManua.ls Logo

Trane Force Flo Cabinet Heater - Page 9

Trane Force Flo Cabinet Heater
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Model Number Descriptions
UNT-SVX07E-EN 9
Digit 30 — Control Type
A = Fan mode switch
E = Tracer ZN010
F = Tracer ZN510
G = Tracer ZN520
H = Customer Supplied Terminal
Interface (CSTI)
J = Tracer UC400, single-zone VAV
K = Tracer UC400 with WCI
Digit 31 — Control Option
D = Unit-mounted fan mode switch
K = Wall-mounted fan mode switch
V = Unit-mounted fan speed switch
with setpoint dial zone sensor
W = Wall-mounted fan speed switch
with setpoint dial zone sensor
X = Unit-mounted fan speed switch
with wall-mounted setpoint dial
zone sensor
Y = Unit-mounted fan speed switch
and wall-mounted setpoint dial
with comm.
Z = Unit-mounted fan speed switch,
On/Cancel, setpoint dial
with comm.
1 = Wall-mounted On/Cancel
with comm.
2 = Wall-mounted fan speed switch,
setpoint dial, On/Cancel
with comm.
0 = Without control option
3 = Unit-mounted low voltage fan
speed switch (Off /Hi /Med /Low)
4 = Wall-mounted digital zone
sensor (OALMH, setpoint,
On/Cancel, comm jack)
5 = Wall-mounted digital zone
sensor (On/Cancel, comm jack)
6 = Wireless zone sensor
7 = Wireless display sensor, unit-
mounted receiver
Digit 32 — IAQ Options (Fan Coil
only)
0 = Without IAQ options
1 = Dehumidification
4 = Dehumidification with sensor
Digit 33 —FLA Motor Option
0 = Standard FLA ECM mode
A = Reduced FLA ECM mode
Digit 34
0 = None
Digit 35 — Control Function #3
(Fan Coil only)
0=None
2 = Condensate overflow detection
Digit 36 — Control Function #4
(Fan Coil only)
0=None
2 = Low temperature detection
Digits 37, 38 — Future Control
Functions
Digit 39 — Projection Panels
and Falsebacks
0=None
A = 5/8-in. standard recessed panel
(vertical recessed units only)
B = 2-in. projection panel
C = 2.5-in. projection panel
D = 3-in. projection panel
E = 3.5-in. projection panel
F = 4-in. projection panel
G = 4.5-in. projection panel
H = 5-in. projection panel
J = 5.5-in. projection panel
K = 6-in. projection panel
L = 2-in. Falseback
M = 3-in. Falseback
N = 4-in. Falseback
P = 5-in. Falseback
Q = 6-in. Falseback
R = 7-in. Falseback
T = 8-in. Falseback
Digit 40 — Main Autoflow GPM
Digit 41 — Auxiliary Autoflow
GPM (Fan Coil only)
Digit 42 — Subbases
0=None
A = 2-in. subbase
B = 3-in. subbase
C = 4-in. subbase
D = 5-in. subbase
E = 6-in. subbase
F = 7-in. subbase
Digit 43 — Recessed Flange
0=None
A = Recessed flange
Digit 44 — Wall Boxes
0=None
A = Anodized wall box
0=None H=3.5
A=0.5 J=4.0
B = 0.75 K = 4.5
C=1.0 L=5.0
D=1.5 M=6.0
E=2.0 N=7.0
F=2.5 P=8.0
G=3.0
0 = None H = 3.5
A=0.5 J=4.0
B = 0.75 K = 4.5
C=1.0 L=5.0
D=1.5 M=6.0
E=2.0 N=7.0
F=2.5 P=8.0
G=3.0

Table of Contents

Related product manuals