EasyManuals Logo
Home>Trane>Air Conditioner>R-410A Split System

Trane R-410A Split System User Manual

Trane R-410A Split System
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #36 background imageLoading...
Page #36 background image
The condition and process of defrosting
When frost is detected in the condenser, the system will enter into defrosting state. When
defrosting starts, the compressor and indoor fan will stop, and the outdoor fan and four-way valve
will delay 30 seconds to stop. The compressor will start again after 30s and. When the compressor
has run for 8mins, the compressor will stop.
After 30 seconds the four-way valve opens and after another 60 seconds, the compressor and
outdoor fan resume running. The indoor fan will delay 2 minutes to run at the latest and
temperature on the display panel shows H1.
Under heating mode,when the compressor is stopped by malfunction, the indoor fan will blow at
low fan speed for 60s and then stop.
Protection
Overcurrent protection
If total current is high, the compressor will run in limited or dropped frequency. When total
current go on rising over the stated value, the compressor will stop, the outdoor fan will delay
30 seconds to stop.
FAN mode
In this mode, the indoor fan will run the fan in High, Med, Low and Auto mode. The compressor,
outdoor fan and four-way valve will stop.
In this mode, the temperature setting range is 16~30ºC.
The unit will adjust the running frequency of the compressor automatically according to the change
of ambient temperature.
AUTO mode
In this mode, the system selects COOL, HEAT and FAN mode automatically according to the change
of ambient temperature. The protection function is the same with that of COOL/HEAT mode.
The unit will adjust the running frequency of the compressor automatically according to the change
of ambient temperature.
Other control
ON / OFF
Each time the On/Off button of the remote controller is pressed, the On/Off state will switch once.
MODE selection
Press the MODE button on the remote controller to select and display the following modes: AUTO,
COOL, DRY, FAN, and HEAT.
Stop heating
Original running state
Reversal valve
Indoor fan
Outdoor fan
Stop
Start heating
Compressor
Tset
Tset
Tamb
3min
Run
2min 2min
36

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane R-410A Split System and is the answer not in the manual?

Trane R-410A Split System Specifications

General IconGeneral
BrandTrane
ModelR-410A Split System
CategoryAir Conditioner
LanguageEnglish

Related product manuals