18
CG-SVX039C-GB
CGAF CGAF CGAF CGAF CGAF CGAF CGAF CGAF CGAF CGAF
80 90 100 110 130 140 150 165 180 190
XE XE XE XE XE XE XE XE XE XE
Option Additional
shipping weight (6)
Single pump - Standard
head pressure
(kg) 215 230 225 235 235 245 240 305 330 325
Single pump - High head
pressure
(kg) 265 275 270 270 270 320 315 315 340 340
Twin pump - Standard
head pressure
(kg) 305 315 315 335 335 345 340 450 475 470
Twin pump - High head
pressure
(kg) 385 400 395 395 395 480 475 475 500 495
Pump VFD option (kg) 70 70 70 70 70 70 70 70 70 70
Partial heat recovery
option (Digit 19 = N)
(kg) 45 45 45 65 65 75 75 75 75 75
Partial heat recovery
option (Digit 19 = P)
(kg) 45 45 45 45 45 75 75 75 75 75
Water Buffer tank option (kg) 250 250 250 250 250 330 330 330 330 330
System data
Nb of refrigerant circuit # 2 2 2 2 2 2 2 2 2 2
Minimum cooling load
% (6)
% 25 23 25 21 25 15 17 15 14 17
Total number of capacity
steps
# 4 8 4 8 4 14 6 14 14 6
Standard/Partial Heat
Recovery Unit
R410A refrigerant
charge Circuit 1 /
Circuit 2
(kg)
22.0 /
22.0
27.4 /
27.4
27.6 /
27.6
28.4 /
28.4
29.4 /
29.4
39.0 /
39.0
39.0 /
39.0
39.0 /
39.0
43.0 /
43.0
43.5 /
43.5
Oil charge Circuit 1 /
Circuit 2 (Digit 19 =
N/C)
(l)
14.2 /
14.2
14.3 /
14.3
14.4 /
14.4
14.4 /
14.4
14.4 /
14.4
22.4 /
22.4
22.6 /
22.6
22.5 /
22.5
22.4 /
22.4
22.4 /
22.4
Oil charge Circuit 1 /
Circuit 2 (Digit 19 = P)
(l)
16.2 /
16.2
16.3 /
16.3
16.4 /
16.4
16.4 /
16.4
16.4 /
16.4
24.4 /
24.4
24.6 /
24.6
24.5 /
24.5
24.4 /
24.4
24.4 /
24.4
POE Oil type OIL058E / OIL057E
(1) Indicative performance at Evaporator water temperature: 12°C / 7°C - Condenser air temperature 35°C - for detailed performances, on a given unit,
consult Order Write Up.
(2) Under 400V/3/50Hz.
(3) Rated Condition without Pump Package.
(4) Electrical & system data are indicative and subject to change without notice. Please refer to unit nameplate data.
(5) If the power line of the unit is protected by fuses gG of the same size as the disconnect switch.
(6) For detail information refer submittal drawing which are available in the unit.
General Data
Table 3 – General data CGAF 080-190 Extra Efficiency (continued)