Trane SINTESIS ADVANTAGE CXAF 100 SSE User Manual

Trane SINTESIS ADVANTAGE CXAF 100 SSE
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
CG-SVX039C-GB
June 2021
Confidential and proprietary Trane information
Original instructions
CGAF Air-Cooled Scroll Chillers
CXAF Air to Water Scroll Heat Pumps
260 - 710 kW
Installation
Operation
Maintenance
Question and Answer IconNeed help?

Do you have a question about the Trane SINTESIS ADVANTAGE CXAF 100 SSE and is the answer not in the manual?

Trane SINTESIS ADVANTAGE CXAF 100 SSE Specifications

General IconGeneral
ModelSINTESIS ADVANTAGE CXAF 100 SSE
CategoryChiller
Operating Voltage400V/3Ph/50Hz
Refrigerant TypeR134a
Sound Power Level85 dBA

Summary

Unit Model Number Description

Model Number Breakdown

Detailed breakdown of each digit in the unit model number and its meaning.

Pre-Installation

Mandatory Start-up Checklist

Checklist for technicians before unit start-up, covering installation tasks.

General Data

Table 1 - CGAF 090-190 Standard Efficiency

Technical specifications for CGAF Standard Efficiency units.

Table 2 - CGAF 080-190 High Efficiency

Technical specifications for CGAF High Efficiency units.

Table 5 - CXAF 080-110 Standard Efficiency

Technical specifications for CXAF Standard Efficiency units.

Table 8 - CXAF 130-190 High Efficiency

Technical specifications for CXAF High Efficiency units.

Installation Requirements

Lifting and Moving Instructions

Detailed instructions and warnings for safely lifting and moving the unit.

Evaporator Piping

Evaporator Flow Switch

Minimal Installation Water Content

Importance of water volume for temperature stability and avoiding short cycles.

Installation - Mechanical

Schematic pump package

Evaporator Waterside

Freeze Protection

Options for freeze protection based on ambient temperature and glycol use.

Freeze Protection with Glycol

Guidance on selecting glycol concentration for freeze protection.

General Electrical Recommendations

WARNING! Hazardous Voltage with Capacitor!

Safety precautions for handling capacitors and discharging stored energy.

Hazardous Voltage - Pressurized Burning Fluid!

Warnings regarding pressurized refrigerant and high voltage during servicing.

Electrical Data

Where to find electrical data like power input, amps, and short circuit rating.

Installer-Supplied Components

Operating Principles

Operating Map

Total Heat Recovery

Table 9 - General Data for Total Heat recovery (THR) Option CGAF 080-190

General data for the Total Heat Recovery option on CGAF units.

Partial Heat Recovery Option

Table 12 - General Data for Partial Heat recovery CGAF 090-190 Standard Efficiency

General data for Partial Heat Recovery option on CGAF Standard Efficiency units.

Optional Free-Cooling

Table 17 - General data for free-cooling option sizes 080-190

General data for free-cooling options on CGAF units.

Controls/Tracer TD7 Operator Interface

Pre-Start Checkout

Installation Checklist

Checklist to verify installation procedures are completed before unit start.

Unit Voltage Power Supply

Procedure to check supply voltage and ensure it meets installation section criteria.

Unit Voltage Phasing

Importance of establishing correct compressor rotation and phase sequence.

Unit Start Up Procedures

Periodic Maintenance

Compressor Service Information

Compressor Electrical Connections

Importance of correct wiring for DSH compressor rotation and avoiding damage.

Compressor Replacement

Steps for replacing a failed compressor, including oil and filter drier changes.

Condenser Coils MCHE Maintenance

Integrated Pump Maintenance

BPHE Evaporator Maintenance

BPHE Evaporator replacement

Steps and precautions for correctly replacing the BPHE evaporator.