18-GJ05D1-12A-EN
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
Important: This Document is customer property and is to remain with this unit. Please return to service information
pack upon completion of work.
Important: These instructions do not cover all variations
in systems nor provide for every possible contingency to
be met in connection with the installation. Should further
information be desired or should particular problems
arise which are not covered sufficiently for the pur-
chaser’s purposes, the matter should be referred to your
installing dealer or local distributor.
Note: The manufacturer recommends installing ONLY
AHRI approved, matched indoor and outdoor systems.
Some of the benefits of installing approved matched
indoor and outdoor split systems are maximum efficien-
cy, optimum performance, and the best overall system
reliability.
Note: All AHRI ratings use a 90 second fan off delay.
Use your branded thermostat or separate relay to enable
this delay.
Note: Condensation may occur on the surface of the air
handler when installed in an unconditioned space. When
units are installed in unconditioned spaces, verify that
all electrical and refrigerant line penetrations on the air
handler are sealed completely.
Important: TAM4A0C60S51 air handler applied in
downflow or horizontal configurations should not exceed
2000 CFM. Airflow above 2000 CFM could result in
water blow-off. For verification, see airflow table.
Important: The TAM4 air handlers will only use the fol-
lowing internal electric heaters:
BAYEAAC04BK1, BAYEAAC04LG1
BAYEAAC05BK1, BAYEAAC05LG1
BAYEAAC08BK1, BAYEAAC08LG1
BAYEAAC10BK1, BAYEAAC10LG1
BAYEAAC10LG3, BAYEABC15BK1
BAYEABC15LG3, BAYEABC20BK1
BAYEACC25BK1
Convertible Air Handlers
1-1/2 – 5 Ton
Black Epoxy Coil
TAM4A0A18S11ED
TAM4A0A24S21ED
TAM4A0A30S21ED
TAM4A0A36S31ED
TAM4A0B42S31ED
TAM4A0C48S41ED
TAM4A0C60S51ED
Installer’s Guide
Standard Coil
TAM4A0A18S11SD
TAM4A0A24S21SD
TAM4A0A30S21SD
TAM4A0A36S31SD
TAM4A0B42S31SD
TAM4A0C48S41SD
TAM4A0C60S51SD
Note: Representative illustrations only included
in this document. Most illustrations display the
upflow configuration.
Question and Answer IconNeed help?

Do you have a question about the Trane TAM4A0A36S31ED and is the answer not in the manual?

Trane TAM4A0A36S31ED Specifications

General IconGeneral
BrandTrane
ModelTAM4A0A36S31ED
CategoryAir Handlers
LanguageEnglish

Summary

Safety Information

General Safety Precautions

Covers electrical hazards, hazardous vapors, corrosion risks, and sharp edge safety warnings.

Unit Preparation

Preparing the Unit for Installation

Steps to check for damage, transport, and prepare the unit for installation, including coil pressure checks.

Placing the Unit

Vertical Installation

Upflow Installation Procedures

Details specific installation methods for upflow configurations, including TASB and Plenum installations.

Downflow Installation Requirements

Covers requirements and steps for downflow installation, including code compliance and specific warnings.

Horizontal Installation

Horizontal Installation Guidelines

Addresses considerations for horizontal installation, emphasizing level positioning, proper support, and auxiliary drain pan.

Ductwork Connection

Refrigerant Lines

Refrigerant Line Brazing

Brazing Refrigerant Connections

Step-by-step instructions for brazing refrigerant lines, including panel removal and connection procedures.

Condensate Drain Piping

Low Voltage Electrical

High Voltage Electrical

System Start Up

System Start-Up Procedure

Step-by-step instructions for powering up the system, including thermostat settings and power connection.

Sequence of Operation

Checkout Procedures

Post-Installation System Checks

A checklist of procedures for verifying proper installation and system operation after completion.