18
18-GF74D1-1R-EN
Minimum Airflow CFM
TEM6A0B24H21SC, TEM6A0B30H21SC
Heater Minimum Heater Airflow CFM
With Heat Pump Without Heat Pump
BAYHTR1504BRK, BAYHTR1504LUG
BAYHTR1505BRK, BAYHTR1505LUG
660 600
BAYHTR1508BRK, BAYHTR1508LUG
780 600
BAYHTR1510BRK, BAYHTR1510LUG
780 600
BAYHTR1517BRK
1050 850
BAYHTR3510LUG
780 600
BAYHTR3517LUG
900 850
TEM6A0C36H31SC, TEM6A0C42H41SC
Heater Minimum Heater Airflow CFM
With Heat Pump Without Heat Pump
BAYHTR1504BRK, BAYHTR1504LUG
BAYHTR1505BRK, BAYHTR1505LUG
875 675
BAYHTR1508BRK, BAYHTR1508LUG
950 820
BAYHTR1510BRK, BAYHTR1510LUG
1000 820
BAYHTR1517BRK
1000 820
BAYHTR3510LUG
875 820
BAYHTR3517LUG
1000 950
BAYHTR1523BRK
1300 1140
TEM6A0C48H41SC, TEM6B0C60H51SA
Heater Minimum Heater Airflow CFM
With Heat Pump Without Heat Pump
BAYHTR1504BRK, BAYHTR1504LUG
BAYHTR1505BRK, BAYHTR1505LUG
1200 975
BAYHTR1508BRK, BAYHTR1508LUG
1350 975
BAYHTR1510BRK, BAYHTR1510LUG
1350 975
BAYHTR1517BRK
1365 975
BAYHTR3510LUG
1300 975
BAYHTR3517LUG
1365 1120
BAYHTR1523BRK
1365 1300
BAYHTR1525BRK
1810 1505