Heater Pressure Drop Table
Airflow
CFM
Number of Racks Heater Racks
1 2 3 4 Heater Model No. of Racks
Air Pressure Drop — Inches W.G.
BAYHTR1504 1
1800 0.02 0.04 0.06 0.14 BAYHTR1505 1
1700 0.02 0.04 0.06 0.14 BAYHTR1508 2
1600 0.02 0.04 0.06 0.13 BAYHTR1510 2
1500 0.02 0.04 0.06 0.12 BAYHTR1517 3
1400 0.02 0.04 0.06 0.12 BAYHTR3510 3
1300 0.02 0.04 0.05 0.11 BAYHTR3517 3
1200 0.01 0.04 0.05 0.10 BAYHTR1523 4
1100 0.01 0.03 0.05 0.09 BAYHTR1525 4
1000 0.01 0.03 0.04 0.09
900 0.01 0.03 0.04 0.08
800 0.01 0.03
700 0.01 0.02
600 0.01 0.02
Subcooling Adjustment
System Matched with: Indoor Unit Model No. Outdoor Model No. Subcooling
16 SEER HP — 2 ton TEM6A0C36H31 4TWR6024H1000A
4TWX6024H1000A
4A6H6024H1000A
13 Degrees
15 SEER HP — 2 ton TEM6A0B24H21
TEM6A0B30H21
4TWR5024G1000A
4A6H5024G1000A
14 Degrees
15 SEER HP — 3 ton TEM6A0B30H21
TEM6A0C36H31
TEM6A0C42H41
4TWR5036G1000A
4A6H5036G1000A
14 Degrees
All other matches must be charged per the nameplate charging instructions
Subcooling Adjustment for TEM6A0C48H41 & TEM6B0C60H51
Sub-Cooling Charge Specification For AHRI Rated Performance
OD Equipment Up Flow / Horizontal Down Flow
AC UNIT OD Name Plate OD Name Plate
HP UNIT ≤ 3.5 Tons OD Name Plate OD Name Plate
+ 4 Degrees
HP UNIT = 4 and 5 Tons OD Name Plate OD Name Plate