7 H-Frame Size Disassembly and Assembly Instructions
7.1 Electrostatic Discharge (ESD)
CAUTION
Frequency converters contain dangerous voltages when
connected to the main voltage. Never perform any
disassembly when power is applied. Remove power to
the frequency converter, and wait until the frequency
converter capacitors fully discharge. Only a competent
technician must carry out the service.
Many electronic components within the frequency
converter are sensitive to static electricity. Voltages so
low that they cannot be felt, seen, or heard can reduce
the life, aect performance, or completely destroy
sensitive electronic components.
CAUTION
Use correct ESD procedures to prevent damage to
sensitive components when servicing the frequency
converter.
NOTICE
Frame size is used throughout this manual where ever
procedures or components dier between frequency
converters based upon the unit's physical size. Refer to
chapter 1.4.1 Frame Size Denitions to determine frame
size.
7.2 General Disassembly Procedure
This procedure explains how to remove the outer parts of
the frequency converter that are common for H frame
sizes. When this procedure is completed, the inside
components are accessible.
1. Remove the plastic cover beneath the LCP with a
at-edged screwdriver.
2. Loosen and remove 4 screws (T20) on the front
cover.
3. Remove the front cover.
7.3 H6 Frame Size Disassembly and
Assembly Instructions
7.3.1 Control Card and Control Card
Mounting Plate
1. Remove the LCP and the protection foil
underneath it.
2. Remove the 3 screws (T10) from the control card.
3. Remove the control card.
4. Remove the 4 bolts on the bottom of the frame
underneath the cable connector.
5. Remove the screws (T10) in the control card
mounting plate.
6. Press barbs on ribbon cable and remove it.
7. Remove screws (T20) in cover plate.
8. Remove the control card mounting plate.
Reinstall in the reverse order.
H-Frame Size Disassembly a... TR150 and TR170 Service Manual
BAS-SVM04B-EN 02/2017 All rights reserved. 57