Model Number Descriptions
8 UNT-SVX07J-EN
UniTrane™ Fan Coil
Low Vertical Model
Following is a complete description
of the UniTrane fan coil low height
vertical model.
Digits 1, 2 — Unit Type
FC = Fan Coil
Digit 3 — Unit Model Type
K = Low vertical concealed
L = Low vertical cabinet
Digit 4 — Development
Sequence
B = Development B
Digit 5, 6, 7— Unit cfm
030= 300 cfm
040= 400 cfm
060= 600 cfm
Digit 8 — Unit Voltage
1 = 115 V/60 Hz/1 PH
2 = 208 V/60 Hz/1 PH
3 = 277 V/60 Hz/1 PH
4 = 230 V/60 Hz/1 PH
Digit 9 — Piping system
placement
C = Without piping, Right hand, With
aux drain pan
D = Without piping, Left hand, With
aux drain pan
J = With piping, Right hand, With
aux drain pan
K = With piping, Left hand, With
aux drain pan
Digit 10, 11— Design Sequence
** = Factory assigned
Digit 12 — Inlet
A = Front toe space
B = Front bar grille
Digit 13 — Outside Air Damper
0=None
B = Manual, Back opening
E = Auto, 2-position, Back
opening
Digit 14 — Outlet
G = Top quad grille
H = Top bar grille
J = Top duct collar
Digit 15 — Unit Color
0=None
1 = Deluxe beige
2=Soft dove
3=Cameo white
4 = Driftwood grey
5 = Stone grey
6=Rose mauve
7 = To be selected later
Digit 16 — Tamperproof Locks/
Leveling Feet
0=None
B = Keylock access door
D = Leveling feet
F = Keylock access door with
leveling feet
Digit 17 — Coil Type
A = 2-row cooling/heating
B = 3-row cooling/heating
C = 4-row cooling/heating
D = 2-row cooling, 1-row heating
E = 2-row cooling, 2-row heating
F = 3-row cooling, 1-row heating
K = 2-row cooling/heating, Electric
heat
P = 2-row cooling/heating, 1-row
heating
Q = 2-row cooling/heating
,
2-row
heating
R = 3-row cooling/heating,1-row
heating
X = 2-row cooling only, Electric heat
Digit 18 — Air Vent (Coil)
0=None
A=Auto
M= Manual
Digit 19, 20, 21 — Electric Heat
kW
000= None
010 = 1.0 kW (0.75 kW 208 V)
015 = 1.5 kW (1.1 kW 208 V)
020= 2.0 kW (1.5 kW 208 V)
025= 2.5 kW (1.9 kW 208 V)
030= 3.0 kW (2.2 kW 208 V)
040= 4.0 kW (3.0 kW 208 V)
Digit 22 — Reheat
0=None
C = Electric Heat (N/A)
Digit 23 — Disconnect Switch
0=None
D = With disconnect switch
Digit 24 — Filter Type
0=None
1 = 1 in. throwaway filter
Digit 25 — Future Option
0=None
Digit 26 — Future Option
0=None
Digit 27 — Piping Packages
0=None
A = Basic - Ball valve supply and
return
B = Basic - Ball valve supply and
manual circuit setter return
E = Deluxe - Ball valve supply and
manual circuit setter return
F = Deluxe - Ball valve supply and
return with auto flow
Digit 28 — Control Type
0=None
A = Fan speed switch
D = Tracer®ZN010
E = Tracer® ZN510
F = Tracer® ZN520
H = Customer Supplied Terminal -
STAT Interface
L = Tracer® UC400-B
M = Tracer® UC400-B with Wireless
Communications Interface
(WCI)
N = CSTI with fan status
P = Tracer® UC400-B - WCI and CO
2
Digit 29 — Control Options
0=None
V = Unit-mounted zone sensor
module (OALMH and Setpoint
dial)
W = Wall-mounted zone sensor
module (OALMH and Setpoint
dial)
X = Unit-mounted fan mode switch,
Wall-mounted (Setpoint dial)
Y = Unit-mounted fan mode switch,
Wall-mounted zone senor
(Setpoint dial, ON/CANCEL,
Comm. jack)
Z = Unit-mounted zone sensor
module (OALMH, Setpoint dial,
ON/CANCEL buttons)
1 = Wall-mounted zone sensor
module (ON/CANCEL buttons,
Comm. jack)
2 = Wall-mounted zone sensor
module (OALHMH, Setpoint dial,
ON/CANCEL, Comm. jack)
4 = Wall-mounted digital zone
sensor (OALMH, Setpoint,
ON/CANCEL, Comm. jack)
6 = Wireless zone sensor (Setpoint
dial, Occupied/Unoccupied
buttons)
7 = Wireless display sensor, unit
receiver (OALMH)
8 = Unit-mounted variable speed
control
9 = Wall-mounted variable speed
control
Digit 30 — IAQ (N/A)
0=None
1 = Dehumidification
3 = Polymer drain pan
4 = Stainless steel drain pan
Digit 31 — FLA Motor Option
0 = Standard ECM
A = Reduced FLA
Digit 32 - Control Option
0 = None
A = Low limit sensor
B = Condensate overflow
C = Low limit and condensate
Overflow
Digit 33 — Main Valve Type
0=None
A = 2-way, 2-position N.C.
B = 2-way, 2-position N.O.
C = 3-way, 2-position N.C.
D = 3-way, 2-position N.O.
E = 2-way, Modulating
F = 3-way, Modulating
G = 2-way, Analog (2-10 VDC)
H = 3-way, Analog (2-10 VDC)
J = Field supplied, 2-position N.C.

Table of Contents

Other manuals for Trane UniTrane

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane UniTrane and is the answer not in the manual?

Trane UniTrane Specifications

General IconGeneral
BrandTrane
ModelUniTrane
CategoryHeater
LanguageEnglish

Related product manuals