SAFETY WARNING
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-
conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment
by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and
on the tags, stickers, and labels that are attached to the equipment.
Installation, Operation,
and Maintenance
UniTrane™ Fan Coil and Force-Flo™ Cabinet Heater
200 - 1200 CFM
Models FC and FF, Low Vertical Models FCKB and FCLB
UNT-SVX07E-EN
March 2014

Table of Contents

Other manuals for Trane UniTrane Fan-Coil

Questions and Answers

  • M
    Michael LeeAug 15, 2025
    What to do if my Trane Air Conditioner motor fails to start?
    • C
      Claudia BerryAug 16, 2025
      If your Trane Air Conditioner motor fails to start, it could be due to several reasons. If the current supply is improper, contact your power company for adjustments. If there is a mechanical failure, check that the fan rotates freely. If there is low line voltage, check across the AC line and correct the voltage if possible.
  • T
    ttranAug 18, 2025
    What to do if my Trane Air Conditioner has missing filters?
    • J
      jessica58Aug 18, 2025
      If your Trane Air Conditioner is missing filters, replace them.
  • C
    Christina JohnsonAug 22, 2025
    What to do if my Trane Air Conditioner motor overheats?
    • J
      Jacob PenaAug 22, 2025
      If your Trane Air Conditioner's motor overheats, several factors could be responsible. Begin by checking the voltage at the motor terminals and correct any voltage loss if possible. Ensure that the line wiring to the motor is adequately sized, replacing it with larger wiring if necessary. Reduce the motor load or consider replacing it with a larger motor if it's overloaded. Inspect the motor fan for obstructions, removing the fan cover to clean the fan if it's clogged with dirt. Tighten any loose motor mounting bolts. Replace rigid coupling connections with flexible connections. Finally, check for and remove any interference causing the fan to rub on the fan cover.
  • B
    Brandy VaughnAug 25, 2025
    What to do if my Trane Air Conditioner has low water coil capacity?
    • M
      Megan ArnoldAug 25, 2025
      If your Trane Air Conditioner has low water coil capacity, start by inspecting the water pumps and valves for proper operation and check the lines for any obstructions. Also, adjust the chiller or boiler to ensure the proper water temperature. Clean the fin surface.
  • C
    Christine BallardAug 27, 2025
    What to do if my Trane Air Conditioner has excessive vibration?
    • S
      Shawn AdamsAug 27, 2025
      If your Trane Air Conditioner is experiencing excessive vibration, check the fan alignment by aligning and retightening the bearing set screws. Also, ensure that all shipping spacers and/or bolts have been removed.
  • V
    victoriayoungAug 31, 2025
    How to fix wet interior of Trane Air Conditioner?
    • H
      haysdavidAug 31, 2025
      To address a wet interior in your Trane Air Conditioner, consider these solutions: reduce the fan speed if the coil face velocity is too high. Repair any leaks if the drain pan is leaking or overflowing. Insulate the surfaces if condensation is forming on them.
  • S
    Sarah JohnsonSep 2, 2025
    How to fix a blown fuse in my Trane Air Conditioner?
    • S
      Sarah AndersonSep 2, 2025
      If your Trane Air Conditioner has a blown fuse or an open circuit breaker, replace the fuse or reset the circuit breaker.
  • J
    juancrawfordSep 6, 2025
    What to do if my Trane Air Conditioner motor runs and then dies down?
    • L
      Laura GarzaSep 6, 2025
      If your Trane Air Conditioner motor runs and then dies down, check for loose connections. Also, determine the adequacy of the main power supply.
  • H
    Harry MendozaSep 9, 2025
    What to do if my Trane Air Conditioner has an overload trip?
    • M
      Michael MurphySep 9, 2025
      If your Trane Air Conditioner experiences an overload trip, check and reset the overload.
  • L
    lauraraySep 12, 2025
    What to do if my Trane Air Conditioner has improper wiring or connections?
    • T
      tmarquezSep 12, 2025
      If your Trane Air Conditioner has improper wiring or connections, check the wiring with the diagram supplied on the unit.

Summary

Warnings, Cautions and Notices

Proper Field Wiring and Grounding Required

Ensures safe installation by emphasizing qualified personnel and code compliance for electrical connections.

Personal Protective Equipment (PPE) Required

Stresses the necessity of using appropriate PPE for potential electrical, mechanical, and chemical hazards during installation.

Installation-Mechanical

Installing the Unit

Step-by-step procedures for properly installing vertical and horizontal units, including panel removal and securing.

Coil Piping and Connections

Installation - Zone Sensors

Address Setting

Step-by-step process for setting rotary address switches to establish communication between sensors and receivers.

Associating Sensor to Receiver

Procedures for establishing communication between wireless sensors and receivers, including manual and automatic methods.

Installation - Controllers

Installation - Electrical

MCA and MOP Calculations

Details on calculating minimum circuit ampacity and maximum overcurrent protection for electric heat units.

ECM Overview and Setup

Electronically Commutated Motor (ECM)

Introduction to ECM motors, their integrated features like overload protection, and electrical connections.

VelociTach Motor Control Board

Overview of the motor control board's functions, user interface, status display, and troubleshooting capabilities.

Safety Requirements

Critical safety recommendations for working with ECM motors and control boards, emphasizing electrical hazards.

Motor Control Board Settings

Explains parameter settings on the motor control board for configuring fan speed, electric heat, and other operational parameters.

Startup

Pre-Startup Checklist

A comprehensive checklist to ensure all installation procedures are complete before initiating unit startup.

Occupancy Modes

Explains how occupancy modes are controlled via communicated signals, sensors, or timed overrides.

Unit Protection Strategies

Outlines built-in strategies like Smart Reset and Freeze Protection to safeguard the unit and building from damage.

Routine Maintenance

Maintenance Checklist

A schedule of recommended weekly, monthly, and annual maintenance tasks for ensuring optimal unit performance.

Diagnostics and Troubleshooting

Fan Coil and Cabinet Heater

A troubleshooting guide for common fan coil and cabinet heater issues, listing symptoms, probable causes, and recommended actions.

Trane UniTrane Fan-Coil Specifications

General IconGeneral
TypeFan-Coil
Heating CapacityVaries by model
Voltage208/230V, 277V
Control OptionsThermostat
AirflowVaries by model
Sound LevelVaries by model
CabinetGalvanized steel with powder coat finish
InsulationFiberglass
Filterthrowaway