SAFETY WARNING
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing
of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and
training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or
serious injury. When working on the equipment, observe all precautions in the literature and on the tags,
stickers, and labels that are attached to the equipment.
UniTrane™ Fan Coil and Force-Flo™ Cabinet Heater
200-1200 CFM
Models FC and FF
Low Vertical Models FCKB and FCLB
Installation, Operation,
and Maintenance
UNT-SVX07J-EN
June 2018

Table of Contents

Other manuals for Trane UniTrane

Questions and Answers

  • R
    rodriguezbernardJul 31, 2025
    Why is my Trane Heater electric heat not operating?
    • J
      Jeanette JohnsonJul 31, 2025
      The electric heat in your Trane Heater might not be operating due to several reasons: * The controller may be cycling the electric heat on and off to meet the unit capacity requirements, which is normal operation. * There might be no power to the controller. To operate normally, the controller needs a 24 Vac input voltage. If the green LED is off continuously, the controller may not have sufficient power or may have failed. * Incorrect or missing wiring between the controller outputs and the electric heat contacts can prevent normal operation. * The controller might not be properly configured based on the installed devices and application. If the unit configuration doesn't match the actual device, the electric heat might not work correctly.
  • C
    Charles SandersAug 4, 2025
    Why does the fan on my Trane UniTrane Heater not energize?
    • A
      Ashley StuartAug 5, 2025
      If the fan on your Trane Heater does not energize, check the following: * Ensure the wiring between the controller outputs and the fan relays and contacts is correctly connected for normal fan operation. * Verify the controller has sufficient power. It needs an input voltage of 24 Vac. If the Marquee/Power LED is OFF continuously, the controller may lack sufficient power or has failed. * Confirm that the controller is properly configured based on the installed devices and application. If the unit configuration does not match the actual end device, the fans may not work correctly.
  • J
    James MaloneAug 9, 2025
    Why does the fresh air damper on my Trane UniTrane stay closed?
    • S
      sscottAug 10, 2025
      If the fresh air damper on your Trane Heater stays closed, consider these potential causes: * Normally, the fresh air damper is open during occupied mode when the fan is running and closed during unoccupied mode. So, it can be normal operation. * Ensure the wiring between the controller outputs and the fresh air damper is correctly connected for normal damper operation. * Verify the controller has sufficient power by applying an input voltage of 24 Vac. If the green LED is off continuously, the controller may lack sufficient power or has failed. * Confirm that the controller is properly configured based on the installed devices and application. If the unit configuration does not match the actual end device, the damper may not work correctly.
  • S
    Sara MirandaAug 14, 2025
    Why does the fresh air damper on my Trane Heater stay open?
    • B
      Brittany RamirezAug 14, 2025
      If the fresh air damper on your Trane Heater stays open, consider these potential causes: * Normally, the fresh air damper is open during occupied mode when the fan is running and closed during unoccupied mode. So, it can be normal operation. * Ensure the wiring between the controller outputs and the fresh air damper is correctly connected for normal damper operation. * Verify that the controller is properly configured based on the installed devices and application. If the unit configuration does not match the actual end device, the damper may not work correctly.
  • U
    uwilliamsAug 19, 2025
    Why does the outdoor air damper remain closed on my Trane UniTrane Heater?
    • T
      Tony MyersAug 19, 2025
      If the outdoor air damper remains closed on your Trane Heater, check the following: * Ensure the wiring between the controller outputs and the outdoor air damper is correctly connected for normal outdoor air damper operation. * Verify the controller has sufficient power by applying an input voltage of 24 Vac. If the Marquee/Power LED is OFF continuously, the controller may lack sufficient power or has failed. * Confirm that the controller is properly configured based on the installed devices and application. If the unit configuration does not match the actual end device, the outdoor air damper may not work correctly.
  • J
    Jonathan JohnsonAug 25, 2025
    Why does the motor spin too fast or without speed request on my Trane Heater?
    • P
      ptaylorAug 26, 2025
      If the motor spins too fast or spins without any apparent speed request on your Trane Heater, check these items: * Verify that the voltage jumper on the motor plug harness is absent for 208-230V units and 277V units, as the motor may not be controllable. * Ensure that the fan speed request is not below 450 rpm, as speeds below 450 rpm are not supported on the fan coil product. * Verify that variable speed (VSP) inputs are properly wired to 1TB4, as output signals may be ignored.

Summary

SAFETY WARNING

Proper Field Wiring and Grounding Required

Personal Protective Equipment (PPE) Required

Follow EHS Policies!

Pre-Installation

Installation-Mechanical

Installation Checklist

Abbreviated guide to detailed mechanical installation procedures.

Installing the Unit

Procedures for properly installing the unit.

Duct Connections

Coil Piping and Connections

Installation - Electrical

Supply Power Wiring

Guidelines for sizing and connecting power supply wiring.

ECM Overview and Setup

Overview

Introduction to the Trane ECM motor and VelociTach control board.

Installation and Initial Setup

Procedures for installing and setting up ECM units.

VelociTach Motor Control Board

Details on the VelociTach motor control board functions and interface.

Motor Control Board Settings

Reference for motor control board parameter names and typical settings.

Installation - Controls

Power Supply Requirements

Critical requirements for controller power supply.

Zone Sensor Options

Zone Sensor Installation

Guidelines for installing zone sensors.

Zone Sensor Settings

Procedures for configuring zone sensors.

Startup

Pre-Startup Checklist

Checklist for verifying installation before unit startup.

Unit Startup

Procedures for starting the unit and controllers.

Routine Maintenance

Diagnostics and Troubleshooting

ECM Motors Troubleshooting

Troubleshooting common issues with ECM motors.

Wiring Diagrams

Typical Wiring Diagram for ZN010 Unit

Wiring diagram for ZN010 unit with single-stage electric heat.

Typical Wiring Diagram for UC400-B Unit

Wiring diagram for UC400-B unit with dual-stage electric heat.

Typical Wiring Diagram for CSTI Unit

Wiring diagram for CSTI unit with 3-phase single-stage electric heat.

Typical Wiring Diagram ZN520 Unit

Wiring diagram for ZN520 unit with dual-stage electric heat.

Typical Wiring Diagram for Tracer ZN520 Unit

Wiring diagram for ZN520 unit with four-pipe configuration.

Typical Wiring Diagram for Tracer ZN510 Unit

Wiring diagram for ZN510 unit with four-pipe configuration.

Typical Wiring for UC400-B Controller with WCI

Wiring diagram for UC400-B controller with WCI.

Trane UniTrane Specifications

General IconGeneral
Voltage208V, 240V, 480V (depends on model)
EfficiencyVaries by model. Consult specific product data.
Control OptionsThermostat
AirflowVaries by model. Consult specific product data.
DimensionsVaries by model. Consult specific product data.
WeightVaries by model. Consult specific product data.