25
Restore Factory Calibration (B6) – wireless systems only
Caution: This action cannot be undone.
1. Switch off the RF digital indicator by pressing and holding the ZERO/OFF key for about 5
seconds.
2. Enter the Setup mode by pressing and holding the ON/PRINT key for about 20 seconds or
until the screen shows “F”.
3. Use the ON/PRINT key to change the display to “B”.
4. Scroll down once using the ZERO/OFF key to enter the “Bluetooth” menu. Scale shows
“B 1”.
5. While in the Bluetooth mode, scroll to "B 6”.
6. Press the ZERO/OFF key once; the display says “F-CAL”.
7. To view all of the factory corner calibration values, press the ZERO/OFF key once; the indi-
cator automatically displays the calibration values for each corner (1-4) in sequence and
then returns to the “F-CAL level.
8. To view all of the factory span calibration values, press the UNITS key once; the indicator
automatically displays the following in sequence and then returns to the “F-CAL” level.
Span Point #1 Weight Value
Span Point #1 A/D Count
Span Point #2 Weight Value
Span Point #2 A/D Count
Span Point #3 Weight Value
Span Point #3 A/D Count
9. To exit without restoring the factory calibration values, press the PRINT key; the indicator
revert backs up to B6.
10. To restore the factory calibration values, press and hold the NET/GROSS key for 3 sec-
onds; the indicator briefly displays “dOnE” and then reverts back up to B6.
11. In order to save all parameters, it is imperative to exit all menus in the following manner: At
the parameter level, press the UNITS (up) key twice (two times) to exit the Bluetooth Menu.
The indicator displays ‘SAvE’ and then automatically powers off.

Other manuals for Transcell Technology TI-500 RF Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Transcell Technology TI-500 RF Series and is the answer not in the manual?

Transcell Technology TI-500 RF Series Specifications

General IconGeneral
BrandTranscell Technology
ModelTI-500 RF Series
CategoryTouch Panel
LanguageEnglish

Related product manuals