IV. CONTROL ARCHITECTURE
COIL SENSOR
3
P/N 337-60071-02
DISCHARGE SENSOR
3
P/N 337-60072-00
HORN
3
P/N 337-60070-00
CABINET SENSOR
3
P/N 337-60069-02
RH SENSOR
3
P/N 337-60080-00
(control versions H only)
3= Component can be ordered separately.
HOLDER CLIP
1
P/N 337-60038-00
HOLDER CLIP
1
P/N 337-60038-00
H1 CONTROLLER
2
TRANSFORMER/
RS485
DOOR RELAY
EVAP BLOWER
RELAY
POWER LINE IN 1
DEFROST COMPRESSOR
RELAY POWER LINE IN 2
DOOR
RELAY
CABINET
AIR
HORN
RH/AMBIENT
AIR
EVAP
COIL
DISCHARGE LINE
1= Set of two (can be ordered separately).
2= Requires unit model number and serial
number to place order.
BLUE SHRINK TUBE
YELLOW SHRINK TUBE
GREEN
SHRINK TUBE