VIII. CONTROL PARAMETERS
VIII. b - PARAMETER ACCCESS & UNITS OF MEASUREMENT:
Control Unit of
Parameter Description Access Measure
ADR* Device Address ENG
BAU* Comm. Baud Rate in K ENG KBaud
NAF* NAFEM Communications Enable ENG On/Off
SPH Temperature Set-Point High CUS Degree
SPL Temperature Set-Point Low CUS Degree
SHL Set-Point High/Low ENG Degree
SHH Set-Point High/High ENG Degree
SLL Set-Point Low/Low ENG Degree
SLH Set-Point Low/High ENG Degree
RO Room Offset CUS Degree
HI Upper Temperature Limit ENG Degree
LO Lower Temperature Limit ENG Degree
SCL Temperature Scale CUS F or C
HAD High-Temperature Alarm Delay ENG Minute
LAD Low-Temperature Alarm Delay ENG Minute
AC Anticylcing ENG Minute
DEF Defrost Type ENG Electric/Gas/Off
IBD Intervals Between Defrosts ENG Hours
DDC Maximum Defrost Duration ENG Minute
CDE Coil Temperature At End of Defrost Cycle ENG Degree
DDE Drip Time At End of Defrost Cycle ENG Minute
BDD Blower Delay At Drip Time ENG Minute
BSD BSD After Defrost End ENG Degree
ODD Display Hold After Defrost ENG Minute
SD Start/Stop Defrost CUS Start/Stop
CFA Clogged Filter Alarm n/a On/Off
CCR Clogged Filter Compressor Run Time n/a Minute
CDL Clogged Filter Alarm Temperature n/a Degree
DOA Door Open Alarm ENG On/Off
DAD Door Display Alarm Delay ENG Minute
APD Alarm Pause Delay ENG Second
ATD Alarm Temperature Delay ENG Second
AAS Audible Alarm Style CUS On/Off
CL Set The Clock Time CUS H/N/S
DAY Set The Clock Date CUS Y/N/D
DS Daylight Savings CUS On/Off
DL1 Defrost Lockout 1 CUS Time/Off
DL2 Defrost Lockout 2 CUS Time/Off
DL3 Defrost Lockout 3 CUS Time/Off
DL4 Defrost Lockout 4 CUS Time/Off
DCF Dewpoint Correction Factor CUS %
CON Compressor Default On Time ENG Minute
COF Compressor Off Time ENG Minute
EL Evaporator Coil Temperature CUS Degree
DL Discharge Line Temperature CUS Degree
CB Cabinet Air Temperature CUS Degree
PLn* Display Line Voltage ENG Volts
RCO* Cycle Compressor Relay ENG On/Off
RdF* Cycle Defrost Relay ENG On/Off
RFA* Cycle Blower/Fan Relay ENG On/Off
RDH* Cycle Door Heater Relay ENG On/Off
PRO* Go To Bootloader For Programming ENG
CEP* Clear EEPROM & Load Defaults ENG
REF* Software Version/Revision/Step n/a
-34-
H1, MIT I & MIT II CONTROL VERSIONS ONLY
*MIT II control version only.