-5-
II. BASIC SERVICE PROCEDURES
II. c - STARTING A MANUAL DEFROST CYCLE (G-Series):
The Display
Will Read
NOTE:
Traulsen G-Series refrigerator models also include an off-cycle
defrost feature, which occurs once an hour. This is
indicated by the control display, is time terminated, and is
generally of 3 - 10 minutes in duration.
The defrost cycle on Traulsen G-Series freezer models can
be either time or temperature terminated.
Step 1: Press . Display will read “CUS.”
Step 2: Press . Display will read “000” with the left digit flashing.
Step 3: Press . Display will read “000” with the center digit flashing.
Step 4: Press until the center digit changes to an “A”.
Step 5: Press . Display will read “0A0” with the right digit flashing.
Step 6: Press until the right digit changes to an “1”.
Step 7: Press . Display will read “SPH”.
Step 8: Press until the control reads “Sd,” Start Manual Defrost.
Step 9: Press . Display will read “n” (NO).
Step 10: Press or . Display will read “4” (YES).
Step 11: Press . Display will then read “SPH,” Start Manual Defrost.
Step 14: Press or to scroll to the next parameter, otherwise the
controller will automatically revert back to normal operation after a delay of
approximately 20-30 seconds.