23
EN
minipool Phantom PR1
U
Use
6
FILLING THE MINIPOOL
During the lling phase, if the times for reaching the
minimum (90 min) and maximum (60 min) levels in the
overow tank are not met, alarms "AL1" (minimum level)
and "AL2 "(maximum level) will be triggered, stopping
all operation.
In this case, you will have to disconnect the power and
restore it after about 30 seconds using the product's main
power switch and check the reason for this anomaly (leaky
pipes, obstructed supply valves, insufcient pressure).
During the use of the minipool the system automati-
cally maintains the water level ush with the edge of the
bathtub.
Automatic lling using the keypad: pressing
the key activates the automatic lling of the
minipool, controlled by two level sensors.
26∞
OK
More information
MAINTAINING THE WATER LEVEL IN THE
MINIPOOL
When the minipool is completely lled a maximum
sensor (SL2) and a minimum sensor (SL1) continuously
monitor the water level inside the compensation tank.
SL1 (minimum sensor) = 0, the sensor does NOT detect water
SL1 (minimum sensor) = 1, the sensor detects water
SL2 (maximum sensor) = 0, the sensor does NOT detect water
SL2 (maximum sensor) = 1, the sensor detects water
If the lack of water is minimal (e.g., evaporation or a
person gets out):
The minimum sensor still detects water (SL1 = 1).
The maximum sensor does not detect water (SL2 = 0).
activates automatic lling until conditions are
restored and for a maximum of 60 minutes.
If the lack of water is considerable (e.g., two or more
people get out of the minipool):
Both the minimum and maximum sensors do not
detect water (SL1 = 0, SL2 = 0).
The recirculation pump moves the water from
the compensation tank to the minipool.
The minimum sensor detects water (SL1 = 1, SL2 = 0).
activates automatic lling until conditions are
restored and for a maximum of 60 minutes.
Perform a preliminary cleaning of the minipool using a
bit of water and a mild detergent.
Do not use cloths or cleaners that are abrasive, aggressive
or that contain solvents because they could irreparably
damage the surface of the minipool.
Do not start any operation until the minipool has
been completely lled, otherwise the minipool
could be damaged.
Before lling, once again check the quality of the water
supply. This is very important for the well-being of the
users and for the long life of the minipool.
AUTOMATIC FILLING USING THE KEYPAD
Once the pool is powered, the display will show the word
"treesse" and after a few seconds the display will show
the current ambient temperature, and the various symbols
on the keypad will be illuminated with white light.
Press the
key on the keypad to activate lling: lling
in progress is indicated by the blue icon.
First, the compensation tank is lled, and then - once
the water has reached the maximum level inside the
tank - the bathtub is lled through a recirculation pump,
passing through the paper lter and the heater.
This cycle will be repeated many times until both the
compensation tank and bathtub are lled. At this stage
and until lling is completed, no other functions of the
minipool - except chromatherapy - will be available.