32
EN
minipool Phantom SP1
If any alarms appear during initial startup, read the instructions provided in the following table. If the solution is not
possible, immediately contact the Manufacturer to request technical support.
In the meantime, do not try to repair or use the minipool but rather disconnect it from the electricity and water supplies.
4B
ALARMS
ALARMS
NOTIFICATIONS
Screen
displayed
DESCRIPTION OF THE PROBLEM
POSSIBLE SOLUTIONS
HI-43
Temperature
alarm
(notication)
Problem description: if the water temperature in the minipool exceeds
42°C all the functions are deactivated, the display shows the "HI" mes-
sage alternating with the temperature value.
Solutions:
the alarm and the system will automatically reset when the
temperature drops. If the alarm does not reset contact the Manufacturer.
Er
Temperature
sensor alarm
(alarm)
Problem description: a temperature sensor measures the water temperature
inside the minipool, activating the heater when necessary.
The allowed water temperatures range from 5°C to 45°C. Values outside
the range cause the blocking of all functions and the permanent activa-
tion of the alarm message.
Solutions:
the alarm will reset automatically once the temperature re-
turns to allowed values (5° to 45°). The message is also displayed if the
temperature sensor malfunctions.
Solutions:
make sure that the water temperature is not outside of the
permitted values, try to disconnect the power supply to the bathtub
and switch it on again after 30 seconds. If the problem persists, verify
that the connection with the control unit is correct and has not been
tampered with. Otherwise contact the Manufacturer.
Fl
No ow
("FL" alternating
with the tempera-
ture)
(notication)
Problem description: When the recirculation is active but the ow switch
does not detect ow for ve running seconds, the heater is disabled, the
recirculation pump remains active for ve minutes, after which it switches
off, the display shows the message "FL" alternating with the temperature.
Solutions:
turn off the pool and clean the lters. Make sure that the
recirculation pump works perfectly. Otherwise contact the Manufacturer.
If the problem persists, all functions are disabled and the display shows
the xed "FL" alarm (obstructed lter).
Fl
Obstructed lter
("FL" xed message)
(alarm)
Problem description: the alarm occurs when, due to lack of ow, the
condition lasts for more than 5 minutes). The system stops, all functions
are disabled and the display shows the xed "FL" alarm.
Solutions:
The alarm resets only by switching off the minipool and turn-
ing it back on after about 30 seconds.
The main causes of what has been described are attributable to:
1
excessive dirt on the lter due to incorrect treatment of the water
inside the minipool (see Use and maintenance manual, par. Water
treatment on page 37).
Turn off the minipool and clean the lter
2
Damage to the ow sensor (contact the Manufacturer).
3
Damage to the circulation pump. Once the minipool restarts, verify
that the circulation pump functions correctly.
Use