DESCRIPTION OF THE PROBLEM
POSSIBLE SOLUTIONS
Co
Water control unit
alarm
(notication)
Problem description: in case of no communication with the chroma-
therapy controller, the system disables the function and the display shows
the "Co" message alternating with the temperature.
The other functions remain available.
Ll
Water level alarm
(notication)
Problem description: the notication is activated if the water level in-
side the compensation tank is below the minimum for more than three
seconds. The display will show the message "LL" alternating with the
temperature, the functions remain enabled, the system will start lling
the minipool to restore the levels (see the section on lling the minipool
on page34
The notication is activated when a number of people leave the bathtub
at the same time (the system automatically restores the level by activat-
ing the ll function).
FER
Water level
sensors alarm
(alarm)
Problem description: the alarm is activated if there is a malfunction of
the level sensors, especially when the system detects the maximum level
but not the minimum level.
Solutions:
try to reset the system by cutting off power to the pool for
about 30 seconds, check that the level sensor cable is not damaged
(e.g., crushed by something), restore power to the minipool.
If the problem persists, contact the Manufacturer.