CHAPTER 1
CHAPTER 1 - PRE-INSTALLATION REQUIREMENTS
1.3.4 Polypropylene (PP) Vent Piping and Fittings
Approved polypropylene vent manufacturers and vent
systems:
Centrotherm Eco Systems, LLC
DuraVent
Z-Flex U.S. Inc.
ECCO Manufacturing
Only use approved polypropylene components listed
in Table 2 on page 4 to Table 5 on page 6. Termi-
nation must be selected from the options shown in this
manual, using UV-resistant polypropylene.
Contact approved polypropylene vent man-
ufacturer for a copy of their installation in-
structions. Read, understand and follow all
of the vent manufacturer’s instructions be-
fore beginning the installation. Contact vent
manufacturer if you require any technical
support. Failure to properly install and sup-
port vent system can cause the venting sys-
tem to fail, resulting in substantial property
damage, serious injury, or death.
A specific vent adapter may be required to
transition from the boiler vent outlet adapt-
er to the specific polypropylene vent system.
Contact the appropriate PP vent manufac-
turer for transition adapter information.
When using Polypropylene for the vent sys-
tem, PVC or CPVC pipe meeting the listed
requirements in this manual may be utilized
for the combustion air piping.
WARNING
NOTICE
1.4. Vent/Combustion Air Equivalent
Lengths
For all venting applications, PVC/CPVC, AL29-4C®,
SS or Polypropylene, the length must not exceed
the lengths listed in Table 8 below.
For PVC/CPVC or AL29-4C® vent systems, reduce
the maximum allowable length for each elbow as
follows:
3 feet for every 45º elbow
5 feet for every 90º elbow
For polypropylene vent systems, reduce the maxi-
mum allowable length for each elbow as follows:
5 feet for every 45º elbow
10 feet for every 90º elbow
1.5. Vent Restrictions
1.5.1 2 Inch (60 mm) Vent System Restrictions
The 2 inch vent system requires a 1 inch clearance
to combustibles.
Use long sweep elbows to limit pressure drop and
to avoid excessive vent temperatures.
In 2 inch PVC vent applications, the rst 7 equivalent
feet of the vent system must utilize CPVC material.
To avoid vent failure, the installer must use
CPVC vent material for the first 7 equivalent
feet of a 2 inch PVC vent system. The installer
must also utilize primer and glue that is cer-
tified for both PVC/CPVC materials. Failure to
comply with this requirement can cause the
venting system to fail, resulting in substantial
property damage, serious injury, or death.
WARNING
Table 6 - Maximum Allowable Vent or Combustion Air Piping Length
INSTINCT
Model
2 Inch [60 mm] Piping
OR
3 Inch [80 mm] Piping
Feet Elbows Feet Elbows
Solo 110 33 0 100 0
Solo 155 33 0 100 0
Solo 199 N/A N/A 100 0
Combi 155 33 0 100 0
Combi 199 N/A N/A 100 0

Table of Contents

Other manuals for TriangleTube Instinct Solo Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TriangleTube Instinct Solo Series and is the answer not in the manual?

TriangleTube Instinct Solo Series Specifications

General IconGeneral
BrandTriangleTube
ModelInstinct Solo Series
CategoryBoiler
LanguageEnglish

Related product manuals