Option 1 (CAN keypad connected to network):
1. Hold the (5 / 6) (3) button of keypad for 5 seconds. The keypad
will beep and the LEDs will flash.
2. Enter authority code. The buzzer stays on.
3. Hold (9 / 0) (DB) for 5 seconds. A double-beep plays.
4. The receiver module is now in e-FOB learn mode. (The LED
under the receiver enclosure will be blinking rapidly).
5. Next press lock button of each transmitter to be trained. (LED
stays solid for 2 seconds as each one is trained.) Press the
transmitter button for 0.5-2.0 seconds. A three second delay
must occur between each transmitter.
6. After 60 seconds of e-FOB button inactivity, or by simply
pressing any key on the keypad, 4 beeps will sound and the
module will return to normal operation.
Option 2 (no CAN keypad connected to network):
1. Remove power from module.
2. Move DIP switches 4-6 to the “ON” position.
3. Connect module to CAN network.
4. Connect power and GND to module (J1 P4,16 and J1 P7,19).
5. Wait about 5 seconds. LED will flash continuously.
6. Press any transmitter button for about 5 seconds until LED
pattern changes, then release. This trains the first transmitter.
7. Press any button of 2nd transmitter, LED pattern changes
immediately. This synchs the 2nd transmitter.
8. Repeat step 7 until all transmitters are trained.
9. Remove power from module.
10. Move DIP switches 4-6 to normal position and verify DIP
switches 1-3 are in proper position.
11. Reconnect power to module.
12. Verify that FOBs are synched to the CAN module. CAN module
needs to be connected to a valid CAN network (2+ modules on
network) or CAN must be disabled to verify functionality.
Note:
 Up to 10 transmitters can be synched with a module. If a 11th
transmitter is added an earlier transmitter becomes invalid.
 All transmitters must be trained together. Putting the module into
train mode erases all previous FOBs.