EasyManua.ls Logo

Trimec rt11 - Overview; LCD Displays

Trimec rt11
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 Introduction
1.3 Overview
The RT series instruments are specifically designed for computing, displaying and
transmitting totals and flowrate from flowmeters with pulse or frequency outputs.
The instrument will display Flow Rate, Resettable Total and an Accumulated Total in
engineering units as programmed by the user. Simple flow chart programming with scrolling
English prompts guide you through the programming routine greatly reducing the need to
refer to the instruction manual. All user program data is retained if the battery is removed.
Special Features
Standard
: 10 point Linearisation, PIN Protection, NPN/PNP selectable autoranging pulse
outputs (scaled or un-scaled), Low frequency cut-off, Battery conservation mode.
Optional : 4~20mA output, High / Low flow alarms with adjustable deadbands, Dual inputs.
Environments
The RT is weatherproof to IP66 (Nema 4X) standards, UV resistant glass reinforced nylon
with stainless screws & viton O-ring seals.The instrument suits harsh indoor and outdoor
environments & conforms to EMC directive 89/336/EEC Electro Magnetic Compatibility.
Conforming standards include: EN 61326 ( immunity in industrial locations )
EN 62326 ( emissions in industrial locations )
EN 60529 ( degrees of protection [ IP ] )
Installation
Specifically engineered to be directly mounted on a variety of flowmeters, wall or surface
mounted, pipe or panel mounted. Various mounting kits are available. The instrument can be
self powered or may be powered by an external dc supply or two wire loop powered.
1.4 LCD displays
Programming 17
6.4 Program detail record
Your back up 4 digit PIN number is 1820
To remember consider the model No. RT - “R” is the 18th & “T” the 20th letter of the alphabet.
Pencil your program details here
K =
Units / Sec Min Hr Day
L7
User selected PIN No.
K-factor (scale factor)
Engineering units
Time base for Rate
L1
L4
L3
RCF= yes no
Rate conversion factor
L6
L8
Rate dampening
Decimal for Accum. total
Decimal for Rate
Decimal for reset Total
L5
4mA @
20mA @
@
%
@
%
yes no
yes no
yes no
A+B A-B A
÷
B
K =
L14
L17
Alarm outputs
L15
L16
L20
L21
L18
L19
-
high deadband
-
low set point
-
low deadband
-
high set point
Analog output
-
zero set point
-
span set point
Dual flow inputs
-
K
-
factor
for B input
-
dual input function
L22
L23
L24
Ultra save Standby Continuous
L13
Power mode
3F Hz
K-factor =
4F Hz
K-factor =
5F Hz
K-factor =
6F Hz
K-factor =
7F Hz
K-factor =
8F Hz
K-factor =
9F Hz
K-factor =
2F Hz
K-factor =
1F Hz
K-factor =
0F Hz
K-factor =
yes no
L12
Non linear correction
-
frequency 0
-
frequency 1
-
frequency 2
-
frequency 3
-
frequency 4
-
frequency 5
-
frequency 6
-
frequency 7
-
frequency 8
-
fre
quency 9
percentage
percentage
0 0.0 0.00 0.000
0 0.0 0.00 0.000
0 0.0 0.00 0.000
L11 pulse value = yes no
Pulse output
Hertz = L9
Low frequency cut
-
off
L10
Full LCD display test feature illuminates all
display segments and script text displays for 5
seconds when entering the program mode.
Ltr
gal
m3
lbs
kgs
RUN ACCUM. TOTAL STOP BAT LOW HIGH RATE
The 8 digit Accumulative Total
display can be
programmed for up to 3 decimal places. Reset
is only possible when in the program mode
which can be PIN protected for security.
gal
ACCUM. TOTAL
Rate
display has flashing SEC, MIN, HR or DAY
followed by up to 5 digits of rate programmable
for up to 3 “floating” decimal places.
Ltr
RATE
The 8 digit Total display is push button or
remote resettable and can be programmed for
up to 3 decimal places.
TOTAL
lbs

Related product manuals