Do you have a question about the Trinity XPERT-PRO and is the answer not in the manual?
Lists the main capabilities and measurement features of the Xpert-Pro electrical power meter.
Details input voltage, current, PT/CT ratios, and output relay specifications of the meter.
Provides accuracy and range for power, energy, and power quality measurements.
Covers bezel size, cutout, depth, operating temperature, and weight of the meter.
Step-by-step instructions for connecting the meter in a 3P4W electrical system.
Instructions for installing and wiring the meter in a 3P3W electrical system.
Guide for connecting and installing the meter in a 1P2W single-phase system.
Diagram illustrating the wiring connections for different system types.
Describes the initial display and operation modes after power-up.
Configuration for demand power calculation based on KVA or KW and integration period.
Procedure to select the electrical system type (3P4W, 3P3W, 1P2W).
Configuring the Potential Transformer (PT) gain ratio for accurate voltage readings.
Configuring Current Transformer (CT) primary and secondary ratios for accurate current readings.
Configuring Device ID and Baud Rate for Modbus RTU communication.
Setting parameters for K1 alarm relay: ON condition, value, and time delay.
Setting parameters for K2 alarm relay: ON condition, value, and time delay.
Configuring the time interval for automatic scrolling through Run Mode pages.
Setting options for counting operational time (Run Hour or Load Run Hour).
Procedures for resetting accumulated energy values and demand power.
Explanation of various data pages displayed in Run Mode for 3P4W systems.
Details on Run Mode display pages for 3P3W systems, excluding individual PF.
Details on Run Mode display pages for 1P2W single-phase systems.
Guidelines for using relay contacts and safety precautions for connections.
Parameters, values, and time delays for programming alarm functions on relays.
Information on connecting the meter to SCADA/EMS systems via RS485.
Details on using Modbus RTU for data retrieval and communication parameters.
Table mapping Modbus addresses to system parameters for different configurations.
Explanation of multiplication factors used for various parameters in data transmission.
Information on exception codes returned during communication errors or invalid requests.
Lists the main capabilities and measurement features of the Xpert-Pro electrical power meter.
Details input voltage, current, PT/CT ratios, and output relay specifications of the meter.
Provides accuracy and range for power, energy, and power quality measurements.
Covers bezel size, cutout, depth, operating temperature, and weight of the meter.
Step-by-step instructions for connecting the meter in a 3P4W electrical system.
Instructions for installing and wiring the meter in a 3P3W electrical system.
Guide for connecting and installing the meter in a 1P2W single-phase system.
Diagram illustrating the wiring connections for different system types.
Describes the initial display and operation modes after power-up.
Configuration for demand power calculation based on KVA or KW and integration period.
Procedure to select the electrical system type (3P4W, 3P3W, 1P2W).
Configuring the Potential Transformer (PT) gain ratio for accurate voltage readings.
Configuring Current Transformer (CT) primary and secondary ratios for accurate current readings.
Configuring Device ID and Baud Rate for Modbus RTU communication.
Setting parameters for K1 alarm relay: ON condition, value, and time delay.
Setting parameters for K2 alarm relay: ON condition, value, and time delay.
Configuring the time interval for automatic scrolling through Run Mode pages.
Setting options for counting operational time (Run Hour or Load Run Hour).
Procedures for resetting accumulated energy values and demand power.
Explanation of various data pages displayed in Run Mode for 3P4W systems.
Details on Run Mode display pages for 3P3W systems, excluding individual PF.
Details on Run Mode display pages for 1P2W single-phase systems.
Guidelines for using relay contacts and safety precautions for connections.
Parameters, values, and time delays for programming alarm functions on relays.
Information on connecting the meter to SCADA/EMS systems via RS485.
Details on using Modbus RTU for data retrieval and communication parameters.
Table mapping Modbus addresses to system parameters for different configurations.
Explanation of multiplication factors used for various parameters in data transmission.
Information on exception codes returned during communication errors or invalid requests.
The XPERT-PRO is a microcontroller-based electrical power meter designed for measuring and displaying various electrical parameters. It features a 128x64 backlit LCD for sequential display of information and four front-facing LEDs: one for KWh energy calibration, one for RS485 communication status, and two for relay status.
The XPERT-PRO is a versatile meter suitable for three-phase four-wire, three-phase three-wire, and single-phase two-wire systems. It employs the three-wattmeter method for three-phase four-wire systems and the two-wattmeter method for three-phase three-wire systems to calculate system KVA and KW. The unit measures three-phase voltages, currents, frequency, power factors, and individual harmonic data as histograms, including Total Harmonic Distortion (THD). It also captures individual current and voltage waveforms for all three phases. Based on these inputs, it calculates system KVA, KW, and KWh.
The device supports demand measurement for KVA or KW, which is site-selectable, with an integration period of 30 or 15 minutes. It provides two relay contacts for alarm/trip functions, which are programmable for various parameters, including sliding demand powers (KW and KVA). An RS-485 port is available for connection to SCADA/EMS systems, facilitating communication with an RX/TX LED indicator. The meter also offers a KWh Energy Pulse output on an LED, providing 1000 impulses per KWh.
The XPERT-PRO offers an easy-to-use interface for programming all field-programmable parameters. Users can navigate through programming and run modes using dedicated keys.
The XPERT-PRO is designed for trouble-free service once correctly installed. Key considerations for maintenance and longevity include:
| Category | Measuring Instruments |
|---|---|
| Operating Humidity | 10% to 95% RH (non-condensing) |
| Display | LCD with backlight |
| Measurement Range | 0-100% LEL, 0-1000 ppm CO, 0-100 ppm H2S, 0-30% O2 |
| Resolution | 1% LEL, 1 ppm CO, 1 ppm H2S, 0.1% O2 |
| Response Time | <15 seconds (LEL, CO, H2S) |
| Operating Temperature | -20°C to +50°C (-4°F to +122°F) |
| Power Supply | Rechargeable Lithium-ion battery |
| Sensor Type | Catalytic (LEL), Electrochemical (CO, H2S, O2) |
| Data Logging | Yes |
| Connectivity | USB |
| Type | Portable Gas Detector |