12
COMMISSIONING
The first operation of the shower is intended to
flush out any remaining system debris and to
ensure water is purged through the unit. This
operation must be carried out with the flexible
hose screwed to the shower outlet but without
the sprayhead attached.
Make sure the outlet of the flexible hose is
directed to waste.
Check the isolating valves controlling the water
supply to the unit are fully open.
Note: There is no need to fit the cover at
this stage but be aware of live parts when the
electricity is switched on temporarily.
Fit the temperature control onto the splined
spindle (fig.20).
On the PCB, make sure the commissioning link is
positioned on the middle two pins (fig.21).
Switch on the electric supply at the isolating
switch. Water will begin to flow under gravity
pressure.
Once the unit has been commissioned,
disconnect the electricity supply before removing
the commissioning link.
In order to dispel air and to prime both supplies
to the shower unit, turn the temperature control
several times within its rotational limits. ONCE
WARNING!
Before normal operation of the
shower, it is essential that the
commissioning and setup procedure
are correctly completed. Failure to do
so could cause the pump to run dry
without water and invalidate your
guarantee.
WARNING!
Be aware of live parts in the unit
when the electricity is switched on.
DO NOT tamper with any parts and
DO NOT deviate from the following
instructions.
Temperature control
Fig.20
Commissioning
link
Fig.21
Cold
Hot
Fig.22
Fig.23