mini exposed sequential thermostatic mixer shower
10
Flow Regulation
A ow regulator (not supplierd) is used with
high-pressure water systems and may be tted
with any of the water systems listed in the Water
System Requirements section to reduce ow rate
and assist economy.
To t a ow regulator (exible hose connection)
unscrew the outlet adapter. Place the ow
regulator into the rigid pipe connection end;
please note the ow regulator is only designed to
work in one direction (g.13).
The ow regulator for 15mm rigid pipe must be
tted into the shower head.
ANTI-SCALD PROTECTION
It is important that the mixer shower is tested
regularly to prevent the risk of scalding and
guarantee user safety. This can be carried out as
follows: with the mixer blend temperature set
at 38°C isolate the cold water supply. The outlet
ow rate will reduce to a safe level.
Recommended Outlet Temperatures
The BuildCert TMV scheme recommends the
following set maximum mixed water outlet
temperatures for use in all premises:
44°C - for bath ll but see notes below.
41°C - for showers.
41°C - for washbasins.
38°C - for bidets.
The mixed water temperatures must never
exceed 46°C at terminal tting.
The British Burns Association recommends 37°C
to 37.5°C as a comfortable bathing temperature
for children. In premises covered by the Care
Standards Act 2000, the maximum mixed water
outlet temperature is 43°C.
LEAK TESTING
Direct the outlet of the mixer to waste. Open the
isolating valves to the shower and check for leaks.
Remedy any leaks found.
Flow regulator
Water ow
Angled top
section
Hose
connection
end
Outlet adaptor
O ring
15mm rigid pipe
connection end
Top