Trance 2nd generation electric shower
15
REPLACING THE COVER
Refit the trimplate. Turn the POWER selector
spindle clockwise to the position shown in
fig.14.
Turn the stabiliser valve spindle fully clockwise
until resistance is felt (fig.15).
On the cover turn the power selector to
the COLD position (fig.16) and rotate the
temperature control so that it points to 10, the
mimimum flow position (fig.16).
IMPORTANT: Before finally fitting the cover,
the following steps must be taken:
a. Check the plumbing connections are
watertight.
b. Check the terminal block screws are fully
tightened.
c. Make sure the pipe and cable entering
the unit do not prevent the cover locating
correctly to the backplate.
d. Check the power selector is in the STOP
position and the temperature control is in
the 10 position.
Offer the cover to the unit.
Plug the two neons located on the backplate
onto the bracket inside the cover (fig.17). The
neon with the yellow wires clips into the upper
position and the remaining neon fits into the
lower position.
Attached to the START/STOP switch inside the
cover is a two-wire lead. Connect the socket on
the end of the lead to the plug leading from the
backplate (fig.18).
Note: The plug and socket can only fit one way.
Carefully locate the cover tags into the guide
pockets on the backplate and make sure the
wires are not trapped.
Note: DO NOT remove the cable ties in this
unit.
Guide the cover into position so that the knob
spindle locates correctly (minor adjustment may
be necessary to align the knob and spindle).
Should any difficulty arise, recheck the points
above.
While applying slight pressure to the front cover,
secure in place using the three retaining screws.
Fig.14
>POM-GF30<
Fig.15
Fig.17
Fig.16
WARNING
COVER RETAINING SCREWS
ONLY the SUPPLIED SCREWS should be
used. The use of non supplied screws WILL
invalidate product specications & warranty.