Model 3440-L 6–21
6. SPECIAL FUNCTIONS
Prepare the site for measurement. Place the gauge near the core location
and press 〈START/ENTER〉. The display will be:
- NOMOGRAPH -
Reading # 1
Depth: BS
Time:xx sec.
After counting down to zero, the display will be:
Reading # 1
WD:xxxxx PCF
Move gauge and
press START
If more than one reading is to be taken, move the gauge to the next location
and press 〈START/ENTER〉. The gauge will repeat the above sequence
for each reading. When all the readings are completed, the display will be:
Average of x
Reading(s)-
xxxxx PCF
Press ENTER
Press 〈START/ENTER〉 to return to the READY display. Thin layer