M Count: xxx
D Count: xxx
WD: xxx.x PCF
(Use & keys)
DD: xxx.x PCF
% PR: xx.x %
Moist: xxx.x PCF
% Moist: x.x %
Air Void: xx.x %
Void Ratio x.xxx
MOIST CR: x.xxx
DENS. CR: x.xxx
where:
M Count = Moisture counts as read by the gauge
D Count = Density counts as read by the gauge
WD = Wet density in kg/m
3
or pcf
DD = Dry density in kg/m
3
or pcf
%PR = Percent Proctor (This value is valid only if an
appropriate target has been entered for the material
being tested.)
MOIST = Moisture value in kg/m
3
or pcf
% MOIST = Percent moisture
Air Void = See description below
Void Ratio = See description below
MOIST CR = Moisture count ratio
DENS. CR = Density count ratio
Press ON/YES to return to the Ready mode.