Fault Cause Remedy
yellow LED flashes 4 x
(after operating for a longer period of
time, the heater switches to failure)
Summer mode with empty water
container
Switch appliance off and allow to cool,
fill boiler with water
Warm air outlets blocked Check the individual outlet openings
Circulated air intake blocked Remove the circulated air intake blockage
yellow LED flashes 5 x Room temperature sensor or cable faulty Contact Truma Service
yellow LED flashes 7 x Control panel or control panel cable
defective
Contact Truma Service
yellow LED flashes 8 x FrostControl heating element has a
short circuit
Disconnect heating element plug from electronic control
unit, replace heating element
yellow LED flashes 9 x
(approx. 30 seconds after switching
on the heater)
Gas cylinder or quick-acting valve in
the gas supply line closed
Check gas supply and open valves
Gas cylinder empty Replacing a gas cylinder
(after operating for a longer period of
time, the heater switches to failure)
Gas pressure regulation system iced
up
Use regulator heater (EisEx)
Butane content in the gas cylinder too
high
Use propane (butane is unsuitable for heating, particularly
at temperatures below 10°C)
Red LED flashes 1 – 8 times Heater fault Please contact Truma Service.
Determine the flashing code (short, long) if necessary:
red LED on heater electronics.
Green LED still illuminated after
the heater has been switched off
After-running is active to reduce the
temperature of the appliance
No fault. After-run switches itself off after max. 5 minutes
Room heating does not react to
adjustment immediately
After-running is active to reduce the
temperature of the appliance
No fault. After-run switches itself off after max. 5 minutes
After switching on the green and
the red LED illuminate
Faulty electronics Contact Truma Service
If these actions do not remedy the problem, please contact Truma Service.

Table of Contents

Other manuals for Truma CP E classic

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Truma CP E classic and is the answer not in the manual?

Truma CP E classic Specifications

General IconGeneral
BrandTruma
ModelCP E classic
CategoryControl Panel
LanguageEnglish

Related product manuals