Fault Cause Remedy
(only on Combi D 6 E) No 230 V operating voltage
230 V fuse defective
Longer period of non-use, e.g.
over the winter months
Restore 230 V operating voltage
Replace 230 V fuse
Operate the heater in diesel mode for approx. 30 minutes – then
switch over to electric mode
Overheating protection has
been triggered
Reset the overheating protection, allow the heater to cool, remove
the connection cover and press the reset button
Yellow LED flashes 3 x Open window above cowl
(window switch)
Close windows
Yellow LED flashes 4 x Warm air temperature and / or
water temperature exceeded:
Not all warm air ducts are
connected
Warm air outlets blocked
Circulated air intake blocked
Check whether the 4 warm air ducts are connected
Check the individual outlet openings
Remove the circulated air intake blockage
Summer mode with empty
water container
Fill boiler with water
Yellow LED flashes 5 x Room temperature sensor or
cable defective
Contact Truma Service
Yellow LED flashes 6 x Water temperature exceeded in
summer mode
Fill boiler with water
Yellow LED flashes 7 x Control panel or control panel
cable defective
Contact Truma Service
Yellow LED flashes 8 x FrostControl heating element
has a short circuit
Disconnect heating element plug from electronic control unit,
replace heating element
If these actions do not remedy the problem, please contact Truma Service.