10
5. °C / °F temperature display
Select temperature display °C (Celsius) or
°F (Fahrenheit).
hot
Default °F (Fahrenheit).
6. Calibrate temperature sensor (OFFSET)
The temperature sensor of the connected fur-
nace can be adjusted individually to suit the size
of the vehicle.
Setting the offset:
Temperature display Increments Range
°C (Celsius) 1 ± 5°C
°F (Fahrenheit) 1 ± 10°F
hot
Default °F (Fahrenheit).
7. Factory setting (RESET)
The reset function resets the control panel to
the factory settings. All your settings are de-
leted. Newly connected devices are recognized
and recorded in the control panel.
• Switch on the 12VDC power supply of the
control panel and the furnace. With Truma
Combi eco plus and Truma Combi comfort
plus, also switch on the 120VAC power sup-
ply (mains supply).
Reset
• Select RESET with the rotary push button(8).
• Tap the rotary push button(8).
• PR SET is shown in the display.
• Tap the rotary push button(8) to confirm.
hot
When you have confirmed the selection, the
control panel is initialized.
During this process, INIT... is shown in the
display.
Display power supply 120VAC
The icon shows that the 120VAC power supply
(mains supply) is available.
F
hot
The icon is displayed only in combination
with a Truma Combi eco plus or
Truma Combi comfort plus.