Warning
This icon indicates that an operating parameter
has reached an undefined status. In this case,
the furnace continues to operate. When the op-
erating parameter returns to the set range, this
icon extinguishes automatically.
hot
Display warning code
Select the icon with the rotary push button(8).
Tap the rotary push button(8).
The code of the current warning is displayed.
The troubleshooting chart can be used to de-
termine the cause of the warning and rem-
edy the error (see Page 13).
hot
W = Warning
42 = Error code
H = Furnace
Cause remedied / return to setting level
Tap the rotary push button(8).
Cause not remedied / return to setting level
Press the Back button(9)
In this case, the warning is not acknowl-
edged in the control panel and the icon
remains. The furnace remains in warning
status.
Malfunction
In case of a malfunction, the control panel im-
mediately goes to the menu level “Malfunction”
and displays the error code of the malfunction.
The troubleshooting chart can be used to deter-
mine the cause of the warning and remedy the
error (see Page 13).
hot
E = Malfunction
112 = Error code
H = Furnace
Cause remedied / return to setting level
Tap the rotary push button(8).
The furnace is restarted.
This may take a few minutes because of
internal time lags of the connected furnace.
If the cause was not remedied, the mal-
function will occur again and the control
panel will again go to the “Malfunction
menu level.
Cause not remedied / return to setting level
Press the back button.
In this case, the malfunction is not acknowl-
edged in the control panel and the icon re-
mains. The furnace remains in the malfunc-
tion status.
Maintenance
This control panel is maintenance-free.
To clean the front, you can use a non-abrasive
cloth moistened with water (and a neutral soap
solution).

Other manuals for Truma CP plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Truma CP plus and is the answer not in the manual?

Truma CP plus Specifications

General IconGeneral
DisplayLCD
Power supply12 V DC
Quiescent current consumption (at 12 V)Approx. 5 mA
Temperature range-15 °C to +60 °C
Protection classIP20
CompatibilityTruma Combi heaters