4.2 Gap/Black Mark Calibration, Self-test and Dump Mode
While calibrate the gap/black mark sensor, printer will measure the label length, print the internal
configuration (self-test) on label and then enter the dump mode. To calibrate gap or black mark sensor,
depends on the sensor setting in the last print job.
Please follow the steps below to calibrate the sensor.
1.Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED becomes amber and blinking. (Any amber will do during the 5 blinks)
The LED color will be changed as following order.
Amber red (5 blinks) amber (5 blinks) green (5 blinks) green/amber (5 blinks)
red/amber (5 blinks) solid green
4. It calibrates the sensor and measures the label length and prints internal settings then enter the dump
mode.
Note:
1. Sensor calibration can be done by Diagnostic Tool or by power on utility. Please refer to
Diagnostic Tool section for more information.
2. Please select gap or black mark sensor type prior to calibrate the sensor.

Other manuals for TSC DA310 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TSC DA310 Series and is the answer not in the manual?

TSC DA310 Series Specifications

General IconGeneral
Resolution203 dpi
Memory4 MB SDRAM
InterfacesUSB 2.0, Serial (RS-232), Ethernet
InterfaceUSB 2.0, Serial (RS-232), Ethernet
Supported Barcode TypesCode 39, Code 128, UPC-A, UPC-E, EAN-8, EAN-13, PDF417, Data Matrix, QR Code
Operating Temperature41°F to 104°F (5°C to 40°C)
Storage Temperature-40 ~ 60 °C (-40 ~ 140 °F)
Humidity20% to 85% RH (non-condensing)
Power Supply100-240V AC, 50/60Hz
Current Consumption2.5A

Related product manuals