3.10 Replacing the Label Supply Spindle (3” and 1”)
1. Refer to section 3.2 to remove the electronic cover.
2. Uninstall the power supply unit by remove 5 screws (fastened by 7.5 kg±15% kg-cm) on the main board and interface as
indicated below.
3. Remove the 7 screws (fastened by 7.5 kg±15% kg-cm), 2 hex socket cap screws (fastened by 7.5 kg±15% kg-cm), and 1 copper
pillar (fastened by 7.5 kg±15% kg-cm) to uninstall the main board as indicated.