63 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
4. Remove the 2 hex socket cap screws (fastened by 10.5 kg±15% kg-cm) on the electronic side to release the label supply spindle
assembly.
5. For 1” core label spindle, remove the screw of the spindle from the stand.
6. Remove the spindle and install the 1” core label spinel into the slot
7. Lock the screw on the side of the spindle and lock 2 screws on the back of the stand.
8. Reassemble the parts in the reverse procedures.