G3&G3 plus Microinverter
V1.0
11
802.11n:-73dBm(@MCS7
BLE Standard
BLE5.0
BLE Frequency Range
2.402GHz-2.480GHz
BLE Transmitting Power
Max 15dBm
BLE Receiving Sensitivity
-97 dBm
The AC voltage and frequency range may vary depending on specific country grid.
Model
TSOL-MS400
TSOL-MS350
TSOL-MS300
Input Data (DC)
Recommended Module Power (W)
300 ~ 550
300 ~ 550
300 ~ 550
Start-up Voltage per Input (V)
22
Rated Input Voltage (V)
42
MPPT Voltage Range per Input (V)
16~60
Max. Input Voltage per Input (V)
60
Max. Short-circuit Current per Input
(A)
20
20
20
Max. Input Current per Input (A)
14
14
14
Quantity of MPPT
1
Max. Inverter Back-feed Current to
the Array (A)
0
Output Data (AC)
Max. Output Power (VA)
400
350
300
Nominal Continuous Output Power
(W)
400
350
300
Nominal Output Current (A)
1.74
1.52
1.3
Max. Output Current (A)
2
1.59
1.45
Nominal Output Voltage/Range (V)*
220/230/240, 175 270, L/N/PE
Nominal Frequency (Hz)*
50/60
Power Factor
>0.99 default, 0.8 leading 0.8 lagging
Output Current Harmonic Distortion
<3%
Efficiency
Peak Inverter Efficiency
96.7%
96.7%
96.7%
CEC Weighted Efficiency
96.5%
96.5%
96.5%
Nominal Mppt Efficiency
99.9%
99.9%
99.9%
Nighttime Power Consumption
<50mW
<50mW
<50mW
Protection
Anti-Islanding protection
Integrated
Insulation monitoring
Integrated
AC surge protection
TYPE II
AC overcurrent protection
Integrated
AC short-circuit protection
Integrated
AC overvoltage protection
Integrated
Over-heat protection
Integrated
Mechanical Data

Table of Contents