EasyManua.ls Logo

TTControl Vision 312 - 6.6 100 BASE-TX Interface

Default Icon
45 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6. SPECIFICATION OF INPUTS AND OUTPUTS
6.3.5 Characteristics
Symbol Parameter Min Max Unit
C
in
Pin input capacitance 8 12 nF
R
pu
Pull-down resistor to GND 10 12 kΩ
V
IL
Input voltage for low level -1 2 V
V
IH
Input voltage for high level 3 32 V
τ
in
Input low-pass filter 0.1 0.3 ms
6.4 External Wake-up
6.4.1 Pinout
Connector Pin no. Function
C1 10 External Wake-up
6.4.2 Functional description
External Wake-up provides the possibility to wake up the Vision 312 device from the Suspend mode or
Power-off mode by an external event (see figure 10).
6.4.3 Maximum ratings
Symbol Parameter Min Max Unit
V
in
Permanent (DC) input voltage -33 33 V
V
in
Transient peak input voltage 500 ms -50 50 V
6.4.4 Characteristics
Symbol Parameter Min Max Unit
C
in
Pin input capacitance 8 12 nF
R
pu
Pull-down resistor to GND 100 120 kΩ
V
IL
Input voltage for low level -1 2 V
V
IH
Input voltage for high level 3 32 V
τ
in
Input low-pass filter 0.1 0.3 ms
6.5 Service Enable
6.5.1 Pinout
Connector Pin no. Function
C1 27 Service Enable