Project No. File:
Model:
H
@
= 40.124
% Oxygen = 21.14
%O
2
% Carbon = 0.01 %CO2
Stack
Temperature
= 25.81 °C
Barametric
Pressure
= 749.3 mmHg
Stack Static
Pressure
= -1.016 mm H2O
Average Square
root P
= 1.667 P mm H2O
Pressure CFM Pressure
1
2.032 505
5
3.048
2
2.54 505
6
3.048
3
2.54 489
7
3.048
4
2.794 510
8
3.302
Average
8
Meter
Temperature
= 25 °C
Pitot Tube
Coefficient
= 0.84
% Moisture
= 21.58
Sample Rate
= 21.24 Lpm
Ideal Nozzle
Size
9.817 mm
3/8 in
Actual Nozzle
Size Used
in
When numbers are entered into calculator, ideal nozzle
size will be displayed. Enter number here
If ideal nozzle size is not available, locate nearest
number. Enter what nozzle size was used for testing
This number is calculated when device is calibrated
Oxygen inside stack during operation
Carbon Dioxide inside stack during operation
12CA05111
Turbochef Technologies
Calculations needed for Nozzle Size
TC8762
HHB2
# Traverse Points
Temperature inside stack during operation
Barametric pressure at location of meter
Static Pressure inside of duct
Enter pressure differential at each traverse point in mm
H2O, the take square root of P.