19
Captive bolt stunner device
BOLT SPRING AND RUBBER BUFFER WEAR PREMATURELY
TRIGGER CANNOT BE MOVED
This is oen caused by the use of more powerful blank cartridges than sti-
pulated. This can also be an indication of unsuitable ammunition being
used. Use cartridges appropriate to the type of animal.
8. Maintenance and care
The annular spring has twisted. The opening of the annular spring must al-
ways be opposite the trigger. The trigger mechanism is defective or the
trigger is deformed. Send the device in for inspection immediately.
The captive bolt stunner is to be checked at least once when starting work
and should be carefully cleaned several times as required to remove pow-
der residues and prevent corrosion. Such residues can lead to functional
faults and damage. Any defects detected should be rectied immediately.
During all cleaning work, observe the corresponding hazardous substances
ordinance with regard to the labeling and instructions for the materials
used. The maintenance and repair shall be carried out only by capable, aut-
horized and trained personnel!
Use of original parts is always essential to ensure that the safety of the de-
vice is maintained!
» Use hand protection (in order to prevent contact reactions)
» Unscrew headpiece in unloaded condition
» Unscrew lock
» Remove bolt spring (only applicable to the Blitz Kerner
and Kleiner Blitz models), rubber buer and bolt
You can also nd further advice in our video guide on main-
tenance and care our website or directly with this link:
Procedure for maintenance and care