EASERA is used for evaluating and measuring the transmission properties of both spaces
and electrical equipment.
EASE FOCUS is a free 2D ‘aiming’ program that can be used for aligning speaker stacks
and particularly arrays. It uses configuration files in ASCII format made using compiler
software which have the extension .efo.
Use of Turbosound EASE data
Turbosound provides pre-measured EASE data to aid sound system designers in making
appropriate choices with the type and positioning of speakers in the required venue. The
suitability of certain models can be assessed and the installation can be improved by
adapting the frequency response consequently.
The speakers are measured from the centre of an entire globe with 5 degree resolution
and third octave frequency resolution.
EASE data is available from our download FTP server at ftp://ftp.turbsound.com