TUTA S30 GSM POWER SOCKET USER MANUAL
Successful SMS reply
Schedule control: function ON/OFF
WorkDay, StartTime-EndTime
3.5.3 Disable timing switching on the output
Method
The Master user sends following SMS message in order to:
Disable timing switch on the output: #128#0# (20)
Successful SMS reply
Schedule control: function OFF
WorkDay, StartTime-EndTime.
3.6 Auto-control the socket output by temperature
3.6.1 Enable auto-controlled by temperature
Description
The external temperature sensor must be inserted into the I/O port
of TUTA S30. The output status of the socket can be controlled by
the environmental temperature automatically.
If users don’t open the “timed switch on the socket” or “delayed
switch on/off the socket” functions, the socket will control to switch
39