OptiSelect manual powder gun Start-up and operation 23
Start-up and operation
Connecting guide
1. Connect the compressed air supply hose from the com-
pressed air circuit directly to the filter unit main connection on
the rear side of the equipment (connecting 1/4"BSP male
thread). The compressed air connection from the filter unit to
the control unit must be connected
Note:
The compressed air must be free from oil and water!
2. Connect the black hose for fluidizing air to the output 1.5 on
the rear side of the control unit
3. Connect the grounding connection cable to the control unit
with the grounding screw, and connect the 5 m long ground-
ing cable with the clamping clip to the booth or the suspen-
sion device
4. Connect the gun cable plug to the socket 2.3 on the rear side
of the control unit
5. Connect the rinsing air hose to the electrode rinsing air out-
put 1.4 and to the powder gun
6. Attach the injector, connect the powder hose to the injector
and to the powder gun
7. Connect the red hose for conveying air to the corresponding
output 1.2 on the rear side of the control unit and to the injec-
tor
8. Connect the black hose for supplementary air to the corre-
sponding output 1.3 on the rear side of the control unit and to
the injector (this hose is electrically conductive)
9. Connect the mains cable to the plug 2.1 Power IN and screw
it on