E-2/3DB CONTROLLER
E:\Documents and Settings\Administrator\Local Settings\Temporary Internet Files\OLK3\E2-3DB.doc
Rev. 01/13/00; Rev. 07/2000 o2L/H
Rev. 10/2000 (dwgs. 100239, 601, 601-01, 601-02, H02-258, 100031, 279L, 274S, 100089)
Rev. 06/21/00 (Reformatted Text; Revised Pg. 3 (2.4.1, 20 amp to 30 amp)
Pg. 11
2.8.1 Connect at least an 18/20 gauge wire from PCB #1, connector P1-15,
from unit set-up to be the master unit to PCB #1, connector P1-15, of
unit set-up to be the slave unit.
2.8.2 Connect at least an 18/20 gauge wire from TB1-9 of master unit to
slave unit TB2-6.
2.8.3 Connect at least an 18/20 gauge wire (ground) from one (1) chassis
to the other chassis.
2.8.4 Use a single breaker for supply power to all controllers.
2.8.5 Follow standard instructions provided in the manuals supplied with
the controllers.