E-2/3DB CONTROLLER
E:\Documents and Settings\Administrator\Local Settings\Temporary Internet Files\OLK3\E2-3DB.doc
Rev. 01/13/00; Rev. 07/2000 o2L/H
Rev. 10/2000 (dwgs. 100239, 601, 601-01, 601-02, H02-258, 100031, 279L, 274S, 100089)
Rev. 06/21/00 (Reformatted Text; Revised Pg. 3 (2.4.1, 20 amp to 30 amp)
Pg. 22
5.1.9 To remove the flashtube, slide the lamp down to the cable.
5.1.10 To install a flashtube, slide the lamp over the connector on to the
cable with the lamp in the base up position.
5.1.11 Insert the flashtube with the pins aligned with the socket.
5.1.12 Tighten the socket screws snug, then 1/4 turn more.
5.1.13 Reconnect cable connection.
5.1.14 Close the hatch and latch securely.
5.1.15 Close the upper hinge assembly and latch securely.
5.2 RED OBSTRUCTION LIGHTING
The only required maintenance needed to be performed is replacement of
the lamps in the L-810 fixture. Lamps should be replaced after being
operated for not more than 75% of the rated life or immediately upon failure
as per FAA Advisory Circular 70/7460-1J. By following these instructions,
maximum safety and performance can be achieved.
Tools Required: None
5.2.1 LAMP REPLACEMENT
5.2.1.1 Unclasp the two (2) latches and let the bail recline back.
5.2.1.2 Lift the lens up and over the lamp letting the lens hang from
the safety cable.
5.2.1.3 Unscrew the lamp counter-clockwise and remove.
5.2.1.4 Install the new lamp by screwing the lamp clockwise.
5.2.1.5 Re-install the lens making sure it is seated properly on the
base.
5.2.1.6 Re-clasp the two (2) latches.