Care and 
Maintenance
The Model CC3 Sprinklers must be 
maintained and serviced in accordance 
with this section.
Before closing a re protection system 
main control valve for maintenance 
work on the re protection system that 
it controls, permission to shut down the 
affected re protection systems must 
be obtained from the proper authorities 
and all personnel who may be affected 
by this action must be notied.
Sprinklers that are found to be leaking 
or exhibiting visible signs of corrosion 
must be replaced.
Automatic sprinklers must never be 
painted, plated, coated, or other-
wise altered after leaving the factory. 
Modied sprinklers must be replaced. 
Sprinklers that have been exposed to 
corrosive products of combustion, but 
have not operated, should be replaced 
if they cannot be completely cleaned 
by wiping the sprinkler with a cloth or 
by brushing it with a soft bristle brush.
Care must be exercised to avoid 
damage to the sprinklers before, 
during, and after installation. Sprin-
klers damaged by dropping, striking, 
wrench twist/slippage, or the like, must 
be re placed. Also, replace any sprinkler 
that has a cracked bulb or that has lost 
liquid from its bulb. See the Installation 
section.
The owner is responsible for the 
inspection, testing, and maintenance of 
their re protection system and devices 
in compliance with this document, as 
well as with the applicable standards 
of the NATIONAL FIRE PROTECTION 
ASSOCIATION, for example, NFPA 25, 
in addition to the standards of any other 
authorities having jurisdiction. Contact 
the installing contractor or product 
manufacturer with any questions.
It is recommended that automatic 
sprinkler systems be inspected , tested, 
and maintained by a qualied Inspec-
tion Service in accordance with local 
requirements and/or national codes.
Limited 
Warranty
For warranty terms and conditions, visit 
www.tyco-re.com.
Ordering 
Procedure
Contact your local distributor for avail-
ability. When placing an order, indicate 
the full product name and Part Number 
(P/N).
Sprinkler Assemblies with NPT 
Thread Connections
Specify: SIN (specify), K-factor 
(specify), Model CC3 Combustible 
Concealed Space Sprinkler, Specic 
Application, Upright, 200°F (93°C), 
P/N (specify):
TY2199, 4.2K ................. 51-311-1-200
TY3199, 5.6K .................51-301-1-200
Sprinkler Wrench:
Specify: W-Type 6 Sprinkler Wrench, 
P/N 56-000-6-387