Page 1 of 4 MARCH 2022 TFP403
Worldwide
Contacts
www.tyco-fire.com
IMPORTANT
Refer to Technical Data Sheet
TFP2300 for warnings pertaining to
regulatory and health information.
Always refer to Technical Data
Sheet TFP700 for the “INSTALLER
WARNING” that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and
installation can permanently damage
a sprinkler system or its compo-
nents and cause the sprinkler to fail
to operate in a fire situation or cause
it to operate prematurely.
Scan the QR code or enter the URL
in a web browser to access the most
up-to-date electronic version of this
document. Data rates may apply.
docs.jci.com/tycofire/series-lfii-
res-4_9-k-pen-sprinkler-wet
Series LFII Residential
4.9 K-factor Pendent Sprinkler
Wet Pipe Systems
General
Description
TYCO Series LFII Residential 4.9K
Pendent and Recessed Pendent Sprin-
klers (TY2236) are decorative, fast
response, frangible bulb sprinklers
designed for use in residential occu-
pancies such as homes, apartments,
dormitories, and hotels. When aesthet-
ics and optimized flow characteristics
are the major consideration, the Series
LFII Residential Sprinklers (TY2236)
should be the first choice.
The Series LFII Residential Sprinklers
are intended for use in the following
scenarios:
wet pipe residential sprinkler sys-
tems for one- and two-family dwell-
ings and mobile homes per NFPA
13D
wet pipe residential sprinkler sys-
tems for residential occupancies up
to and including four stories in height
per NFPA 13R
wet pipe sprinkler systems for the
residential portions of any occu-
pancy per NFPA 13
The recessed version of the Series LFII
Residential Sprinklers is intended for
use in areas with finished ceilings when
used with one of the following:
A two-piece Style 15 Recessed
Escutcheon with recessed adjust-
ment up to 5/8 in. (15,9 mm) from
the ush pendent position.
A two-piece Style 20 Recessed
Escutcheon with recessed adjust-
ment up to 1/2 in. (12,7 mm) from
the ush pendent position.
The adjustment provided by either
Recessed Escutcheon reduces the
accuracy to which the pipe drops to
the sprinklers must be cut.
The Series LFII Residential Sprinklers
have been designed with heat sensi-
tivity and water distribution charac-
teristics proven to help in the control
of residential fires and to improve the
chance for occupants to escape or be
evacuated.
Corrosion-resistant coatings, where
applicable, are utilized to extend the life
of copper alloy sprinklers beyond that
which would otherwise be obtained
when exposed to corrosive atmo-
spheres. Although corrosion-resistant
coated sprinklers have passed the
standard corrosion tests of the appli-
cable Approval agencies, the testing is
not representative of all possible cor-
rosive atmospheres. Consequently,
it is recommended that the end user
be consulted with respect to the suit-
ability of these coatings for any given
corrosive environment. The effects of
ambient temperature, concentration of
chemicals, and gas/chemical velocity
should be considered, as a minimum,
along with the corrosive nature of the
chemical to which the sprinklers will be
exposed.
NOTICE
The Series LFII Residential Pendent
and Recessed Pendent Sprinklers
(TY2236) described herein must be
installed and maintained in compli-
ance with this document and the appli-
cable standards of the NATIONAL FIRE
PROTECTION ASSOCIATION (NFPA),
in addition to the standards of any
authorities having jurisdiction. Failure
to do so may impair the performance
of these devices.
The owner is responsible for main-
taining their fire protection system
and devices in proper operating con-
dition. Contact the installing contrac-
tor or product manufacturer with any
questions.
Sprinkler
Identification
Number (SIN)
TY2236
TY2236 is a replacement for the TY2234.
Question and Answer IconNeed help?

Do you have a question about the Tyco TY2236 and is the answer not in the manual?

Tyco TY2236 Specifications

General IconGeneral
BrandTyco
ModelTY2236
CategoryIrrigation System
LanguageEnglish

Summary

General Description

Technical Data

Approvals

Lists UL, C-UL, and NSF/ANSI 61 certifications.

Maximum Working Pressure

Specifies the maximum allowable working pressure for the sprinklers.

Discharge Coefficient

Provides the K-factor for calculating water flow rate.

Temperature Rating

Indicates the operating temperature ratings for the sprinklers.

Finishes

Lists available surface finishes for the sprinklers.

Physical Characteristics

Lists the materials used for various sprinkler components.

Operation

Describes the mechanism of sprinkler activation due to fluid expansion.

Design Criteria

Outlines installation and hydraulic design requirements per NFPA standards.

Residential Sprinkler Design Guide

Refers to a separate guide for recommendations beyond standard criteria.

System Types

Confirms suitability for wet pipe systems as per UL and C-UL listings.

Ceiling Types

Lists approved ceiling types for installation, per NFPA standards.

Hydraulic Design (NFPA 13D and 13R)

Details minimum flow rates for NFPA 13D and 13R systems based on coverage.

Hydraulic Design (NFPA 13)

Specifies design sprinkler requirements for NFPA 13 systems.

Obstruction to Water Distribution

Details compliance with obstruction rules for water flow.

Operational Sensitivity

Specifies required deflector-to-ceiling distance for optimal operation.

Sprinkler Spacing

Defines minimum and maximum spacing requirements between sprinklers.

Installation

General Instructions

Provides essential precautions for sprinkler installation.

Pendent Sprinklers

Details the specific steps for installing pendent sprinklers.

Recessed Pendent Sprinklers

Outlines the procedure for installing recessed pendent sprinklers.

Care and Maintenance

General Maintenance

Covers essential maintenance practices and warnings.

Inspection, Testing, and Maintenance

Highlights owner responsibility for system upkeep per NFPA standards.

Limited Warranty

Ordering Procedure

Sprinkler Assemblies

Lists part numbers and specifications for ordering sprinkler assemblies.

Recessed Escutcheon

Provides ordering information for recessed escutcheons.

Sprinkler Wrenches

Details part numbers for specific sprinkler wrenches.

Related product manuals