Lists UL, C-UL, and NSF/ANSI 61 certifications.
Specifies the maximum allowable working pressure for the sprinklers.
Provides the K-factor for calculating water flow rate.
Indicates the operating temperature ratings for the sprinklers.
Lists available surface finishes for the sprinklers.
Lists the materials used for various sprinkler components.
Describes the mechanism of sprinkler activation due to fluid expansion.
Outlines installation and hydraulic design requirements per NFPA standards.
Refers to a separate guide for recommendations beyond standard criteria.
Confirms suitability for wet pipe systems as per UL and C-UL listings.
Lists approved ceiling types for installation, per NFPA standards.
Details minimum flow rates for NFPA 13D and 13R systems based on coverage.
Specifies design sprinkler requirements for NFPA 13 systems.
Details compliance with obstruction rules for water flow.
Specifies required deflector-to-ceiling distance for optimal operation.
Defines minimum and maximum spacing requirements between sprinklers.
Provides essential precautions for sprinkler installation.
Details the specific steps for installing pendent sprinklers.
Outlines the procedure for installing recessed pendent sprinklers.
Covers essential maintenance practices and warnings.
Highlights owner responsibility for system upkeep per NFPA standards.
Lists part numbers and specifications for ordering sprinkler assemblies.
Provides ordering information for recessed escutcheons.
Details part numbers for specific sprinkler wrenches.
Lists UL, C-UL, and NSF/ANSI 61 certifications.
Specifies the maximum allowable working pressure for the sprinklers.
Provides the K-factor for calculating water flow rate.
Indicates the operating temperature ratings for the sprinklers.
Lists available surface finishes for the sprinklers.
Lists the materials used for various sprinkler components.
Describes the mechanism of sprinkler activation due to fluid expansion.
Outlines installation and hydraulic design requirements per NFPA standards.
Refers to a separate guide for recommendations beyond standard criteria.
Confirms suitability for wet pipe systems as per UL and C-UL listings.
Lists approved ceiling types for installation, per NFPA standards.
Details minimum flow rates for NFPA 13D and 13R systems based on coverage.
Specifies design sprinkler requirements for NFPA 13 systems.
Details compliance with obstruction rules for water flow.
Specifies required deflector-to-ceiling distance for optimal operation.
Defines minimum and maximum spacing requirements between sprinklers.
Provides essential precautions for sprinkler installation.
Details the specific steps for installing pendent sprinklers.
Outlines the procedure for installing recessed pendent sprinklers.
Covers essential maintenance practices and warnings.
Highlights owner responsibility for system upkeep per NFPA standards.
Lists part numbers and specifications for ordering sprinkler assemblies.
Provides ordering information for recessed escutcheons.
Details part numbers for specific sprinkler wrenches.
The TYCO Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers (TY2236) are decorative, fast-response, frangible bulb sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. They are particularly recommended when aesthetics and optimized flow characteristics are a primary consideration.
These sprinklers are designed to activate in a fire situation, releasing water to control the fire and improve the chance for occupants to escape or be evacuated. The operation relies on a glass bulb containing a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water.
| Brand | Tyco |
|---|---|
| Model | TY2236 |
| Category | Irrigation System |
| Language | English |