INSTALLATION GUIDE
BEFORE INSTALLATION
Parts
Check that the following parts are included in the packaging:
Figure 1: Sauna heater/control panel parts
1. Sauna heater
2. Herb bowl/air humidifi er
3. Brackets x 4
4. Lock screw B8x9.5 x 1
5. Warning and Caution plates for the room in multiple languag-
es
6. Screws B 4 x 6.5 x 6 for Warning and Caution plates
7. Connectors x 3
8. Bracket screws x 4
9. NTC Sensor, cable length 4 m
10. Clips TC (3-5) x 10 pieces
11. Plastic plugs 25x5 x 2 pcs
12. Screws B6x25 x 2 pcs
13. Screw B4x6,5 x 1 piece
14. Sensor cover
15. Rock guard
16. Protection hose Ø14x150 mm x 3 pcs, for RJ10 cables (sen-
sor, control panel, door switch)
Contact your dealer if anything is missing.
Installation tools
The following tools and materials are needed for installation and
connection:
• level
• tape measure
• electric drill
• screw drivers
Installation planning
Before starting to install your sauna heater:
Plan the sauna heater positioning (see the Heater positioning
- normal installation section, page 4).
Plan the control panel positioning (see the attached instruc-
tions for the control panel for allowable positioning).
Plan the sensor positioning (see Figure 3, page 4).
Position the air intake vent (see the Air intake vent positioning
section, page 5).
Position the air exhaust vent (see the Air exhaust vent posi-
tioning section, page 5).
Plan the electrical installation (see the Connection/wiring
diagram section, page 8).
2
8
6
7
15
5
1
3
4
9
10
11
12
13
14
16
Table 1: Voltage and sauna volume
Model Voltage Sauna volume
min. cu.ft.
Sauna volume
max. cu.ft.
Sense U 7 Elite/Pure
(SPU7)
208 V
240 V
175
175
265
320
Sense U 8 Elite/Pure
(SPU8)
208 V
240 V
250
250
360
440
Installation requirements
To ensure safe use of the heater, check that the following criteria
are met:
Electrical wiring should be installed in accordance with NEC
and all state and local codes.
Fuse size (A) and power cable size (AWG) must be suitable
for the heater (see The section called Connection/wiring
diagram, Page 8.
The sauna ventilation must comply with the instructions in
this manual (see The section called Positioning the inlet vent,
Page 5, The section called Positioning the outlet vent, Page
5).
The position of the sauna heater, control panel, and sensors
must comply with the instructions in this manual.
The heater output (kW) must be suitable for the sauna
volume (cu.ft.) (See Table 1, Page 3). The minimum and
maximum volumes must not be exceeded.
NOTE: A GFCI device is not required by ETL. A GFCI may
be installed if required by local codes. However, GFCI devic-
es will tend to nuisance trip during use of the product.