Contact lost with the heater
network relay board node.
During
operation
Operation is interrupted and
rebooting takes place. For steam
production, emptying takes place
immediately after rebooting is
completed in case there is water in
the tank.
Shown when the primary has lost contact with the
connected secondary unit, system cures itself.
Check, does the secondary unit have voltage? Test
by removing and refitting the RJ10 synchronization
cable again. Check that one of the pins in the female
RJ10 connector on the circuit board may have
become misaligned or displaced, so that there is no
contact with the connected synchronization cable.
After rectifying the fault, restart the power to both the
primary and secondary.
At off
Reboot. For steam production,
emptying takes place immediately
after rebooting is completed in case
there is water in the tank.
18
Too many secondary units
connected.
During
operation
Error code appears immediately after
voltage is applied to the system,
resulting in the system constantly
rebooting.
Maximum number of units in the system: 1 primary +
2 secondary for Multisteam. 1 primary + 1 secondary
for Tylarium. The error code is first seen on the
display after rectification and system restarting.
At off
Error code appears immediately after
voltage is applied to the system,
resulting in the system constantly
rebooting.
19
Door has been open for
longer than the permitted
time. Current session ends
During
operation
Operation interrupted. Emptying of
the steam production source takes
place 1 hour after the error occurred.
Error code triggered at
standby/operation on of the
sauna/Tylarium at steam only at
operation on.
Weekly calendar entries rescheduled to the following
week. Date calendar entries deleted. If it is known
that the door was closed all the time, test by
disconnecting and reconnecting the RJ10 connector.
Check, is the distance between the switch and the
magnet set correctly? Check that one of the pins in
the female RJ10 connector on the circuit board may
have become misaligned or displaced, so that
contact with the connected RJ10 cable has been
lost. Pins 3-4 must be NC (Normally Closed) when
the door is closed.
At off
Cannot be triggered when the
system is off.
20
Door switch has been open
for longer than 60 seconds
since the previous session.
During
operation
Error code is only triggered at off.
Arrange it so that the steam room
cannot be started via calendar
entries and external control. Error
code first triggered hidden with the
system off, and first shown at the
start attempt, and at later starts at
the Pure control panel.
Check that the door switch is working by: 1. Restart
the system with the door open, then inspect the
configuration menu status, the door switch will not
now be shown as connected. 2. Close the door and
now the door switch will be shown as closed. If its
shown as not closed, is the switch or cable faulty are
incorrectly installed? Check by removing and refitting
the RJ10 connector. Check, is the distance between
the switch and the magnet set correctly? Check that
one of the pins in the female RJ10 connector on the
circuit board may have become misaligned or
displaced, so that contact with the connected RJ10
cable has been lost. Pins 3-4 must be NC (Normally
Closed) when the door is closed.
At off
Error code is only triggered at off.
Arrange it so that the steam room
cannot be started via calendar
entries and external control.