DocNo.FM0411issueJPage15
14.TENANTSUNITALARMS
FromtheProgrammingmenu,select“TenantsUnitAlarms”tosetthe4hardwiredalarminputtypesoneachintercom.Note;these
inputsareonlyavailableonintercomswithoutatelephoneconnected.
The4programmableinputsareshownonthewebpageinthefollowingorder:
INPUT1
(47Konterminal19)
default42=LowTemp
INPUT2
(18Konterminal19)
default34=DoorExit
INPUT3
(47Konterminal18)
default44=Gas
INPUT4
(18Konterminal18)
default49=CO
AllinputdevicesmustprovideN/Ocleancontactswhichcloseonalarm.
Usethecontactstoswitch0Vwiththecorrectvalue(18K/47K)seriesresistor.
EntertheTynetecCodeforeachdevicetypefromthelistbelow;
12=CeilingPullcord
30=InactivityAlarm
(PIR)
33=BedOccupancyAlarm
34=DoorExit(defaultINPUT2)
41=HighTemperatureSensor
42=LowTemperatureSensor(defaultINPUT1)
43=SmokeDetector
44=GasDetector(defaultINPUT3)
48=HeatDetector
49=CarbonMonoxideDetector(defaultINPUT4)
50=
IntruderAlarm(PIR)
80=FloodDetector
Click“Submit”toenteranychanges.